Gas supply – weber S-640 User Manual

Page 22

Advertising
background image

22

WWW.WEBER.COM

®

VENTILATION

ƽWARNING: Air holes must be provided in the structure at the
top and bottom to provide ventilation in the event of a gas leak.

Air holes can be located in a low visibility area and should be protected by screening
material to prevent rodents and insects from entering the structure. Air holes will also help
dry moisture.
Summit

®

Built-In cabinet vents are available from your dealer or call Customer Service at

1-800-446-1071.

Note: These drawings are only a reference.
•

Cross ventilation must be incorporated in the supporting structure. We recommend
a minimum of 100 square inches (254 square cm )of venting per side.

•

Vents should be on two sides of the structure.

•

The above drawings are for reference only.

•

Location of the vents should be from the center, outward.

•

Locate the vents at both the bottom of the structure and at the top of the structure.

•

The bottom vents should be as close to ground level as possible. Make sure the
vent area is not blocked by interior supports of the structure.

•

We recommend vents with screens.

•

Access doors to the structure are not considered vents.

•

Clean the vents periodically.

ƽ DANGER: Failure to follow recommended minimum venting
instructions can cause gas to collect in the structure in the
event of a gas leak. This may result in a fi re or an explosion
which can cause serious bodily injury or death, and damage to
property.