Gas supply – weber S-640 User Manual

Page 22

Advertising
background image

22

WWW.WEBER.COM

®

VENTILATION

ƽWARNING: Air holes must be provided in the structure at the
top and bottom to provide ventilation in the event of a gas leak.

Air holes can be located in a low visibility area and should be protected by screening
material to prevent rodents and insects from entering the structure. Air holes will also help
dry moisture.
Summit

®

Built-In cabinet vents are available from your dealer or call Customer Service at

1-800-446-1071.

Note: These drawings are only a reference.

Cross ventilation must be incorporated in the supporting structure. We recommend
a minimum of 100 square inches (254 square cm )of venting per side.

Vents should be on two sides of the structure.

The above drawings are for reference only.

Location of the vents should be from the center, outward.

Locate the vents at both the bottom of the structure and at the top of the structure.

The bottom vents should be as close to ground level as possible. Make sure the
vent area is not blocked by interior supports of the structure.

We recommend vents with screens.

Access doors to the structure are not considered vents.

Clean the vents periodically.

ƽ DANGER: Failure to follow recommended minimum venting
instructions can cause gas to collect in the structure in the
event of a gas leak. This may result in a fi re or an explosion
which can cause serious bodily injury or death, and damage to
property.

GAS SUPPLY