Control panel – Winix Winx Dehumidifer 871 User Manual

Page 4

Advertising
background image

6

7

CONTROL PANEL

1. Power ON/OFF

Pressing

button (1) will turn the machine on.

Pushing again will turn the machine off.

Please note unit may run on and off depending

on humidity levels and programmed humidity set.
2. Select Operating Mode

* Auto Mode

When the unit is turned on for the first time or by

cycling through the settings using the

setting button

(3) until auto indicator (9) is lit, operation begins

in auto mode. "50" will appear in the

display (5)

and the auto indicator

(9) will light up. In this setting,

humidity level and fan speed is adjusted for optimum

comfort (50%) with no manual adjustment needed.

If a

humidity adjustment arrow (15) or fan speed

button (2) is pressed while in auto mode, the unit

will switch to humidity mode automatically.

* Humidity Mode

To set desired humidity level when not in auto mode,

push

setting button (3) until humidity indicator

(10) is lit. The humidity levels will adjust in increments

of 5% beginning at a low of 35% and reaching a

maximum of 70%. Humidity will show in the display

when adjusting humidity level. To adjust humidity

level up or down, press

humidity adjustment

arrows (15) until desired humidity level is reached.

* Cycle Run Time

To set Cycle Run Time, push

setting button (3)

until

cycle run time indicator (11) is lit. In this

setting, the unit will run for either 3, 6, or 12 hours,

then shut off for 3, 6, or 12 hours, then turn on

5. Low Room Humidity Indicator

Low room humidity indicator (7) will light when

unit detects low humidity levels.

3. Select Your Fan Speed

By pressing

fan speed button (2), fan speed will

change. The

indicator (8) of selected fan speed

will light (High or Low). In Auto Mode, fan speed

will adjust the fan speed automatically depending

how close the room humidity is to 50%. For example,

if the room is 70%, the unit will need to pull in air

quickly, so it will turn on high. Once the room

reaches 55%, the unit will slow the amount of air

flow and turn the fan on low. Fan Speed can be

adjusted in all settings except for auto mode.

* Continuous Mode

To set the unit into continuous mode, push

setting

button (3) until continuous indicator (12) is lit.

Continuous mode will run the compressor and fan

continuously until it is powered off or until another

setting is inputted. When continuous mode is

programmed, “Co” will be displayed. Fan speed

can be adjusted in this mode.

4. Water Removal Indicators

* Pump ON

Pump setting button is selected when using the

automatic pump feature with included 18 ft. hose

To select the pump as your water removal option,

press the

pump button (4). When the pump

indicator (13) is on, the pump will automatically

remove the water in the bucket only when the

bucket is full. The pump light must be on at all time

to use this function. It will only turn on for a period

of 30 seconds to remove the water. The pump will

turn off after 30 seconds and not turn on again until

the bucket is full again. It is normal for a small

amount of water to remain in the bucket after the

pump has operated; this is to protect the pump.

The pump button should be off at all times except

when the user chooses this as their option to remove

collected water (See Page 7, Option 3). The pump

option should only be selected when there is a ¼”

hose properly installed in the pump drain location.

If the pump button is pressed when using other

disposal options, E3 (Error message – See page 10)

will be displayed. If other disposal options are

needed, push the pump button again to turn off the

pump function.

* Bucket Full Indicator

When the collection bucket is full,

bucket full

indicator (6) will light. The unit will not run with the

bucket full. Dispose of water and replace bucket

properly.

1

7
8

6

14

15

3

11

4

9

10

13

5

2

12

again in the same cycle. To program Cycle Run

Time, the

cycle run time indicator (11) must be

lit. Cycle Run Time can be adjusted by pushing the

timer adjustment arrows (14) up or down to set

operating time for 3, 6, or 12 hours. The cycle timer

function will continue until you change the setting

or turn the unit power off. In this setting, the unit

will operate on the last humidity setting programmed.

During cycle run time operation, compressor and

fan may shut off depending on programmed

humidity level.

NOTE: THIS UNIT IS EQUIPPED WITH A POWER

FAILURE AUTO RESTART. IN THE EVENT OF

A POWER FAILURE THIS UNIT WILL TURN

BACK ON TO ITS LAST SETTING ONCE POWER

IS RESTORED.

Dehumidifier pint capacity is defined as how

much moisture it can draw out of the air in a

24 hour period in 80 degrees F and 60%

Relative Humidity. Once humidity begins to

drop from 60%, the amount of moisture in

the air begins to fall, which will result in less

water in your bucket.