Spider Stopper Guards

Your Gas Barbecue, as well as any outdoor gas
appliance, is a target for spiders and other insects. They
can nest in the venturi section of the burner tubes. This
blocks the normal gas flow, and can cause the gas to
flow back out of the air shutter. Figure 5. This could result
in a fire in and around the air shutters, under the control
panel, causing serious damage to your barbecue.

Figure 5

Venturi

Venturi fin

Air shutter

We recommend that you inspect the Spider Stopper
G u a rds at least once a ye a r. Also inspect and clean the
Spider Stopper Guards if any of the fo l l ow i n g
symptoms should ever occur.

1.

The smell of gas in conjunction with the burner
flames appearing yellow and lazy.

2 .

Barbecue does not reach temperature.

3 .

Barbecue heats unevenly.

4 .

One or more of the burners do not ignite.

Weber Spider
Stopper Guard

Figure 6

DANGER

Failure to correct these symptoms may

result in a fire which can cause serious bodily
i n j u ry or death and cause damage to pro p e rt y.

MAINTENANCE

Inspection and Cleaning of the Spider
Stopper Guards

To inspect the Spider Stopper Guards, remove the control
panel and look to see if they have dust or dirt on their
outside surfaces. If they are dirty, brush off the outside
surface of the Spider Stopper Guards with a soft bristle
brush (an old toothbrush for example). Check that there
are no gaps in the Spider Stopper Guards’ seams or in
the fit around the burners or valves.

The Spider Stopper Guard is factory installed. It fits
tightly around the air shutter section of the burner tube
and the valve, thereby preventing spiders and other
insects access to the burner tubes through the air
shutter openings. Figure 6.