PROBLEM

CAUSE SOLUTION

Machine will not run

Circuit breaker tripped in
building.

Check and reset.

Power switch failure.

Test switch for continuity and replace if necessary.

Tripped circuit breaker.

Reset.

Faulty power cord.

Replace.

Fuse in motor is blown.

Replace. CAUTION: To reduce the risk of electrical
shock, unplug the machine before opening fuse
holder. Fuse will only open under extreme
conditions. Investigate cause before replacing.

Electrical shock

Equipment not grounded.

Follow grounding instructions exactly.

Receptacle not grounded.

Have an electrician inspect building’s wiring.

Internal

wiring

problem

Ensure that the machine wiring matches the
appropriate wiring diagram. Replace any wires or
components that are short-circuiting.

Repeated circuit

breaker tripping

Mechanical problem.

Higher amp draws indicate a mechanical problem,
find the problem before using the machine.

Faulty

circuit

breaker.

Test circuit for continuity. Replace circuit breaker if
necessary.

Excessive vibration

Pad not centered.

Re-center pad.

Damaged or unevenly
worn pad.

Replace pad. Do not rest machine on pad when not
in use.

Damaged

pad

driver.

Replace.

Pad does not turn but

motor is running

Shear coupling has failed.

Replace coupling.