Whirlpool GH7208XR User Manual

Microwave hood combination, Cabinet opening dimensions

Advertising
background image

PRODUCT MODEL NUMBERS

OVERALL DIMENSIONS

VENTING REQUIREMENTS

GH6208XR
GH7208XR

Electrical:

A 120-volt, 60-Hz, AC-only, 15- or

20-amp electrical supply located in the upper
cabinet as close as possible to the microwave
oven hood. A time-delay fuse or circuit breaker
and separate circuit is recommended.

®

Microwave Hood Combination

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Ref. 8206589

01-03-07

Recommended standard fittings

If the existing vent is round, a rectangular-
to-round adapter must be used and a
rectangular 3" extension vent between the
damper assembly and the adapter must be
installed to prevent sticking of the exhaust
damper.

1 - 3-1/4" x 10"

90° elbow

= 25 ft.

1 - wall cap

= 40 ft.

8 feet straight

= 8 ft.

Length of
3-1/4" x 10" system

= 73 ft.

6" vent system

3-1/4" x 10" vent system

1 - transition

= 5 ft.

2 - 90° elbows

= 20 ft.

1 - wall cap

= 40 ft.

8 feet straight

= 8 ft.

Length of 6" system

= 73 ft.

3-1/4" x 10"
90° elbow

90° elbows

transition

wall cap

wall cap

6 ft.

2 ft.

6 ft.

2 ft.

3-1/4" x 10"
to 6" = 5 ft.

3-1/4" x 10"
roof cap = 24 ft.

3-1/4" x 10"
90

° elbow = 25 ft.

90

° elbow

6" = 10 ft.

3-1/4" x 10"
wall cap =
40 ft.

3-1/4" x 10"
90

° flat

elbow= 10 ft.

45

° elbow

6" = 5 ft.

Recommended vent length
Use 3-1/4" x 10" or 6" vent. The total length of the vent system
including straight vent, elbow, transitions, wall or roof caps
must not exceed the equivalent of 140 feet of
3-1/4" x 10" rectangular or 6" diameter round vent. For best
performance, use no more than three 90° elbows. To calculate
the length of system you need, add the equivalent feet for
each vent piece used in the system. See examples below.

Roof venting

Wall venting

roof cap

3-1/4" x 10"

through-the-roof

3-1/4" x 10"

through-the-wall

wall cap

CABINET OPENING DIMENSIONS

For wall or roof venting methods:
If the wall exhaust method is chosen, be sure that
there is proper clearance within the wall so the vent
fits properly and the damper blade opens fully.
Wall and roof caps must have back-draft damper.
We recommend:
✔ using rigid metal vent.
✔ that length of vent and number of elbows should

be kept to a minimum to provide efficient
performance.

✔ that size of vent should be uniform.
✔ using duct tape to seal all joints in the vent

system.

✔ using caulking compound to seal exterior wall or

roof opening around cap.

✔ two elbows should not be installed together.

We do NOT recommend:
✔ flexible metal vent.

NOTE: If flexible metal vent must be used, calculate
each foot of flexible metal vent as two feet of rigid
metal vent. Flexible metal elbows count twice as
much as standard elbows.

NOTE: The grounded 3 prong outlet
must be inside the upper cabinet.

*30" (76.2 cm) is typical for 66"
(167.6 cm) installation height. Exact
dimension may vary depending on
type of range/cooktop below.

18

¹⁄₄

"

(46.4 cm)

18

¹⁄₄

"

(46.4

cm)

29

⁷⁄₈

" (76.0 cm)

15

¹⁄₂

"

(39.4 cm)

A. 2" x 4" wall stud
B. Grounded 3 prong outlet

66" (167.6 cm) min.

12" (30.5 cm) min.
13" (33.0 cm) max.

A B

30"

(76.2 cm)

typical*

30"

(76.2 cm)

min.