Caution, Multi-stage terminal outputs – White Rodgers 1F85-277 User Manual

Page 4

Advertising
background image

4

NOTE

CHECK THERMOSTAT OPERATION

CHECK THERMOSTAT OPERATION

CHECK THERMOSTAT OPERATION

CHECK THERMOSTAT OPERATION

CHECK THERMOSTAT OPERATION

To prevent static discharge problems, touch side of

To prevent static discharge problems, touch side of

To prevent static discharge problems, touch side of

To prevent static discharge problems, touch side of

To prevent static discharge problems, touch side of
thermostat to release static build-up before touching

thermostat to release static build-up before touching

thermostat to release static build-up before touching

thermostat to release static build-up before touching

thermostat to release static build-up before touching
any keys.

any keys.

any keys.

any keys.

any keys.

Do not allow the compressor to run unless the com-

Do not allow the compressor to run unless the com-

Do not allow the compressor to run unless the com-

Do not allow the compressor to run unless the com-

Do not allow the compressor to run unless the com-
pressor oil heaters have been operational for 6 hours

pressor oil heaters have been operational for 6 hours

pressor oil heaters have been operational for 6 hours

pressor oil heaters have been operational for 6 hours

pressor oil heaters have been operational for 6 hours
and the system has not been operational for at least

and the system has not been operational for at least

and the system has not been operational for at least

and the system has not been operational for at least

and the system has not been operational for at least
5 minutes.

5 minutes.

5 minutes.

5 minutes.

5 minutes.

CAUTION

!

If at any time during testing your system does not operate
properly, contact a qualified serviceperson.

Fan Operation

If your system does not have a G terminal connection, skip to
Heating System.

1. Turn on power to system.
2. Move FAN switch to ON position. The blower should be-

gin to operate.

3. Move FAN switch to AUTO position. The blower should

stop immediately.

Heating System

1. Press SYSTEM button to select the Flame icon ( ). If

the auxiliary heating system has a standing pilot, be sure
to light it.

2. Press

to adjust thermostat setting to 1° above room

temperature. The heating system should begin to
operate. The display should show “STG1”. However, if
the setpoint temperature display is flashing, the compres-
sor lockout feature is operating (see Configuration menu,
item 5).

3. Adjust temperature setting to 3° above room temperature.

If your system configuration is set at MS2, HP2 or HP1,
the auxiliary heat system should begin to operate and the
display should show “STG1+2”.

4. Press

to adjust the thermostat below room tempera-

ture. The heating system should stop operating.

Emergency System

EMER bypasses the Heat Pump to use the heat source
wired to terminal E on the thermostat. EMER is typically used
when compressor operation is not desired, or you prefer
back-up heat only.
1. Press SYSTEM button to select EMER. “EMER” will flash

on the display.

2. Press

to adjust thermostat setting above room

temperature. The Aux. heating system will begin to
operate. The display will show “STG1” flashing “EMER”

and Flame icon ( ) to indicate that the Aux. system is
operating.

3. Adjust temperature setting to 3° above room temperature.

The auxiliary heat system should begin to operate and
the display should show “STG1+2”.

4. Press

to adjust the thermostat below room tempera-

ture. The Aux. heating system should stop operating.

To prevent compressor and/or property damage, if

To prevent compressor and/or property damage, if

To prevent compressor and/or property damage, if

To prevent compressor and/or property damage, if

To prevent compressor and/or property damage, if
the outdoor temperature is below 50°F, DO NOT

the outdoor temperature is below 50°F, DO NOT

the outdoor temperature is below 50°F, DO NOT

the outdoor temperature is below 50°F, DO NOT

the outdoor temperature is below 50°F, DO NOT
operate the cooling system.

operate the cooling system.

operate the cooling system.

operate the cooling system.

operate the cooling system.

CAUTION

!

Cooling System

1. Press SYSTEM button to select the Snowflake icon ( ).
2. Press

to adjust thermostat setting below room

temperature. The blower should come on immediately on
high speed, followed by cold air circulation. The display
should show “STG1”.

3. Adjust temperature setting to 3° below room temperature.

The second stage cooling should begin to operate and
the display should show “STG1+2”.

4. Press

to adjust the temperature setting above room

temperature. The cooling system should stop operating.

Refer to equipment manufacturers' instructions for specific
system wiring information.

You can configure the thermostat for use with either multi-stage
electric heat systems or multi-stage gas systems. When config-
ured for electric heat, the G terminal (blower/fan) will be
energized on a call for heat.

This thermostat is designed to operate a single-transformer
system. If you have a two-transformer system, cut and tape off

Multi-Stage Terminal Outputs

Multi-Stage Terminal Outputs

Multi-Stage Terminal Outputs

Multi-Stage Terminal Outputs

Multi-Stage Terminal Outputs

one transformer. If transformer safety circuits are in only one of
the systems, remove the transformer of the system with NO
safety circuits. If required, replace remaining transformer with
a 75VA Class II transformer. After disconnecting one trans-
former, the two commons must be jumpered together.

Use the terminal output information below to help you wire the
thermostat properly for your multi-stage system. After wiring,
see CONFIGURATION section for proper thermostat configu-
ration.

SYSTEM

SYSTEM

SYSTEM

SYSTEM

SYSTEM

L

L

L

L

L

C*

C*

C*

C*

C*

R

R

R

R

R

W2

W2

W2

W2

W2

E/W1

E/W1

E/W1

E/W1

E/W1

Y2

Y2

Y2

Y2

Y2

Y1

Y1

Y1

Y1

Y1

G

G

G

G

G

O

O

O

O

O

B

B

B

B

B

Multi-stage Malfunction

24 Volt

24 Volt Heat Mode Heat mode Cool Mode Cool Mode Blower/Fan Energized Energized

Energized

Light

(Common) (Hot)

2nd stage

1st stage

2nd stage

1st stage

on call for Cool (and

in Cool

in Heat, Off,

Heat if configured

Mode

Emergency

to Electric Heat)

Modes

THERMOSTAT TERMINALS (MULTI-STAGE)

THERMOSTAT TERMINALS (MULTI-STAGE)

THERMOSTAT TERMINALS (MULTI-STAGE)

THERMOSTAT TERMINALS (MULTI-STAGE)

THERMOSTAT TERMINALS (MULTI-STAGE)

*The 24 volt neutral connection to terminal C on the thermostat is not required if you replace the batteries once a year with fresh “AA” Energizer

®

alkaline batteries.