Waterpik Technologies AQUALINK RS485 User Manual

Aqualink, Rs telelink

Advertising
background image

P hone C able

from W all Jack.

A q ua Lin k R S

Tele L ink B oa rd

To R S 485

4-C onductor

C able

(C able betw een

C ontroller and

P ow er C enter)

2

P rogram

# of rings

(default: 4)

P rogram

access code

(default: 62)

®

re

d

bl

ac

k

ye

llo

w

gr

een

1

Caution

Do not mount the TeleLink PCB in the

AquaLink Power Center. Keep in original

TeleLink enclosure.

!

The TeleLink enclosure will need to be installed as close as possible to a phone jack to keep the phone cord as

short as possible between the phone and the TeleLink. The TeleLink will need the phone cord to communicate with
the house phone. Run the 4-conductor wire from the TeleLink either to the AquaLink Power Center (connect to the
red 4-pin terminal bar) or the AquaLink indoor controller (connect to the red 4-pin terminal bar, the wires may be
doubled-up on the terminal bar). If running the 4-conductor wire to the AquaLink RS Power Center, use a strain
relief on one of the knockouts on the bottom of the Power Center.

NOTE: If you are installing more than one accessory board, order and use a Jandy Multiplex PCB Kit,

(p/n 6584). Never put more than two wires into each of the pins of the red terminal bar. Use the Multiplex PCB
whenever more than two of the 4-conductor wire are being connected.

AquaLink

®

RS TeleLink

Telephone Interface

Installation Instructions- Jandy part #6590

6000 Condor Drive, Moorpark, CA, USA 93021 • 707.776.8200 FAX 707.763.7785

480 S. Service Road West, Oakville, Ontario, Canada L6K 2H4 • 905.844.8233 FAX 905.844.2635

Litho in U.S.A. © Water Pik Technologies, Inc. 2001

Sheet # 6862 Rev. E, 1/01

For Technical Support call 707-776-8200, ext. 260

Advertising