DOUBLE WALL CONNECTOR
SINGLE WALL CONNECTOR
CLEARANCE TO COMBUSTIBLES
CHIMNEY CONNECTOR
V
ENTING
C
OMPONENTS AND
C
ONFIGURATION
 
C
OMPONENTS OF A
V
ENTING
S
YSTEM
DO NOT CONNECT THIS UNIT TO A CHIMNEY
FLUE SERVING ANOTHER APPLIANCE
The complete venting system consists of several 
components: chimney connector, wall thimble, 
wall pass-through, chimney, and liner. It is 
absolutely necessary that if you install all of 
these components, they must remain within the 
clearances to combustibles discussed earlier to 
install your stove safely. To protect against the 
possibility of a house fire, you must properly 
install and constantly maintain the venting 
system. Upon inspection, immediately replace 
rusted, cracked, or broken components. 
 
• The chimney connector is the stovepipe from 
the woodstove to the chimney. The chimney 
connector stove pipe must be 6" (152 mm) 
diameter, 24 MSG or 25 MSG blued steel 
connector pipe. Do not use aluminum or 
galvanized steel pipe - they cannot withstand 
the extreme temperatures of a wood fire.