Weiman Products Deva 100 User Manual

Page 12

Advertising
background image

HearthStone Quality Home Heating Products Inc ®

Model 8220

12


DOUBLE WALL CONNECTOR

SINGLE WALL CONNECTOR

CLEARANCE TO COMBUSTIBLES

CHIMNEY CONNECTOR

V

ENTING

C

OMPONENTS AND

C

ONFIGURATION


C

OMPONENTS OF A

V

ENTING

S

YSTEM

DO NOT CONNECT THIS UNIT TO A CHIMNEY

FLUE SERVING ANOTHER APPLIANCE

The complete venting system consists of several
components: chimney connector, wall thimble,
wall pass-through, chimney, and liner. It is
absolutely necessary that if you install all of
these components, they must remain within the
clearances to combustibles discussed earlier to

install your stove safely. To protect against the
possibility of a house fire, you must properly
install and constantly maintain the venting
system
. Upon inspection, immediately replace
rusted, cracked, or broken components.

• The chimney connector is the stovepipe from

the woodstove to the chimney. The chimney
connector stove pipe must be 6" (152 mm)
diameter, 24 MSG or 25 MSG blued steel
connector pipe. Do not use aluminum or
galvanized steel pipe
- they cannot withstand
the extreme temperatures of a wood fire.


Advertising