STEP 4:

Slide the cooling unit in from the cellar side with the thermo-

stat facing the outside of cellar. The outer flange should be

flush to the wall. Secure the flange to the wall through the

pre drilled holes. The screws should penetrate the studs and/

or frame as well as the upper and lower supports to provide

adequate support for the WhisperKOOL system. Seal all cracks

and gaps around the WhisperKool Slimline unit with an air-

tight sealant or caulking to prevent air leakage.

Note: If you use decorative molding, it should be attached to the walls
and never to the cooling unit.

STEP 5

Attach the condensate drain line

The condensation drain line tube is used to remove excess condensation from the unit to a proper discharge

location. It is important that the drain line tube is properly connected and used to prevent leakage and other

problems associated with excess condensation.

Failure to use the condensation drain line tube will void the warranty on the unit.

STEP 6

If removed, install the grille’s on both sides of the unit and plug in the power cord. The use of an extension

cord is not recommended.