Page 6

Electrical Installation

230 VOLT SUBPANEL WIRING INSTRUCTIONS

NOTE

: The subpanel must be placed within 100 feet of the main electrical service panel, and between 5 (1.5 m) and 50 feet (15 m) away from the

spa. All electrical connections must be made in accordance with the wiring information contained in this manual and on the back of the field wiring

access panel of the control box.
Refer to the wiring diagram below.
1. Connect the #8 AWG, WHITE [NEUTRAL] wire from the Neutral/Ground Bar on the main electrical service to the WHITE [NEUTRAL, Panel

Neutral, Pigtail] of the subpanel.

2. Connect the #8 AWG, BLACK [L1] wire from the main electrical service to the subpanel [terminal L1].
3. Connect the #8 AWG, RED [L2] wire from the main electrical service to the subpanel [terminal L2].
4. Connect the #8 AWG, GREEN wire from the Neutral/Ground Bar on the main electrical service to the GROUND terminal of the subpanel.
5. Connect the #8 AWG, WHITE [NEUTRAL] wire from the subpanel breaker to the Neutral terminal on the spa’s control box.
6. Connect the #8 AWG, BLACK [L1] wire from the subpanel breaker to terminal [L1] on the spa’s control box.
7. Connect the #8 AWG, RED [L2] wire from the subpanel breaker to terminal [L2] on the spa’s control box.
8. Connect the #8 AWG, GREEN wire from the GROUND terminal of the subpanel to the GROUND terminal in the spa’s control box.
9. Bond the spa to all exposed metal equipment or fixtures, handrails, and concrete pad pre N.E.C. and all local codes.

NOTE:

To change from Fahrenheit

to Celsius remove jumper on JP2.

230 Volt

Mallorca

®

&

La Palma

Spa Model

Jumper

Configuration

230 VAC CONVERTED SPA

230 VAC PERMANENTLY CONNECTED SPA

REMOVE POWER JUMPER
FROM TERMINAL BLOCK TO
CONVERT SPA TO OPERATE
AT 230 VAC.

NO POWER
JUMPERS REQUIRED

SEE WIRING
ILLUSTRATION

SEE WIRING
ILLUSTRATION

TERMINAL BLOCK
POWER JUMPER

NOTE:

To change from Fahrenheit

to Celsius remove jumper on JP2.

PERMANENTLY CONNECTED
230 VAC, 40A, 60Hz, MODELS

*ALL CANADIAN SPA MODELS USE #8 AWG GREEN, GROUND.
THESE SPAS ARE INTENDED FOR USE WITH GFCI SUBPANEL PROVIDED.

MORE THAN 5 FEET

THE SUB-PANEL MUST BE
WITHIN SIGHT OF THE SPA

DO NOT EXCEED 50 FEET

SUB-PANEL

WITH GFCI

BREAKERS

MAIN SERVICE

ELECTRICAL

PANEL

230VAC, 50 AMP

2-POLE

CIRCUIT BREAKER

(NON GFCI)

LESS THAN 100 FT.

#8 AWG WHITE, NEUTRAL

#8* AWG GREEN, GROUND

#8 AWG BLACK, L1

#8 AWG RED, L2

N, NEUTRAL, #8 AWG WHITE

GROUND, #8 AWG GREEN*

L1, HOT, #8 AWG BLACK

L2, HOT, #8 AWG RED

CONTROL BOX

230 Volt

Converted

Sorrento

®

&

Trinidad

®

Jumper

Configuration