Crossover® ignition system operations – weber 41081 User Manual

Page 30

Advertising
background image

D-12

Crossover® Ignition System Operations

If the Crossover Ignition System fails to ignite the Left
burner, light the Left burner with a match. If the Left
burner lights with a match, then check the Crossover
Ignition System.

Check that both the white(1) and black(2) ignition

wires are attached properly.

Check that the Crossover Ignition button pushes the

igniter (button) down, and returns to the up position.

Check to see if the igniter is loose in the frame.

Tighten if necessary; See Step “Install igniter” for
correct procedure.
If the Crossover Ignition System still fails to light,
Contact the Customer Service Representative in your
region using the contact information sheet provided
with your manual.

(3)

(2)

(1)

(1)

(2)

9) Reinstall the Spider Stopper Guards. Slightly

rotate the Spider Stopper Guards so that the
seams are in line with the Venturi fins(1). There
should be no gaps in the seams or in the fit around
the burners(2) and valves(3).

ƽ

CAUTION: If the Spider Stopper Guards do not

fit tightly, contact the Customer Service Represen-
tative in your region using the contact information
sheet provided with your manual.

ƽ

WARNING: After reinstalling the gas lines, they

should be leak checked with a soap and water
solution before using the barbecue. (See Step:
“Check for gas leaks.”)

Advertising