Check for gas leaks, Ƽdanger – weber LP Gas Barbecue User Manual

Page 17

Advertising
background image

17

Figure 18

Turn so regulator vent
does not collect water

Hose

Quick disconnect
engaged

Valve handwheel
close clockwise

Tank valve

Collar

Male
fitting

Pressure
relief valve

Tank

Regulator

Regulator
vent

(a)

(b)

(c)

Route the hose so it will not interfere with the scale
indicator rod.

The hose and regulator are connected in the following
manner:

Slide back the collar of the quick disconnect on the tank
valve. Push the male fitting of the regulator into the quick
disconnect, and maintain pressure. Slide the collar closed.
Figure 18 (a). Figure 18 (b) shows the quick disconnect
engaged and various components of the tank and
regulator. Regulator vent hole should be at 3, 6, or 9
o'clock. It should not be pointed up. Figure 18 (c).

Figure 19

Step 17

Check for gas leaks

ƽ

WARNING: You should check for gas leaks every

time you disconnect and reconnect a gas fitting.

Note - All factory made connections have been thoroughly
checked for gas leaks. The burners have been flame
tested. As a safety precaution you should recheck all
fittings for leaks before using your Weber Gas Barbecue.
Shipping and handling may have loosened or damaged a
gas fitting.

ƽ

WARNING: Perform these leak checks even if your

barbecue was dealer or store assembled.

You will need: a soap and water solution and a rag or
brush to apply it.

To perform leak checks: open tank valve by turning the
tank valve handwheel counterclockwise. Figure 19.

ƽ

DANGER

Do not use an open flame to check for gas
leaks. Be sure there are no sparks or open
flames in the area while you check for
leaks. This will result in a fire or explosion
which can cause serious bodily injury or
death and damage to property.

Check for leaks by wetting the connections with the soap
and water solution and watching for bubbles. If bubbles
form or if a bubble grows there is a leak.

Note - Since some leak test solutions, including soap and
water, may be slightly corrosive, all connections should be
rinsed with water after checking for leaks.

ƽ

WARNING: Do not ignite burners when leak checking.

Advertising