Mobile Home - Additional Installation Requirements

The installation of this range must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280). When such standard is not
applicable, use the Standard for Manufactured Home
Installations, ANSI A225.1/NFPA 501A or with local codes.

Mobile home installations require:

When this range is installed in a mobile home, it must be
secured to the floor during transit. Any method of securing
the range is adequate as long as it conforms to the standards
listed above.

Product Dimensions

Freestanding Range

Cabinet Dimensions

Cabinet opening dimensions shown are for 25" (64.0 cm)
countertop depth, 24" (61.0 cm) base cabinet depth and 36"
(91.4 cm) countertop height.

If the cabinet depth is greater than 24" (61.0 cm), oven frame
must extend beyond cabinet fronts by ½" (1.3 cm) minimum.

NOTE: 24" (61.0 cm) minimum when bottom of wood or metal
cabinet is covered by not less than

¹⁄₄" (0.64 cm) flame retardant

millboard covered with not less than No. 28 MSG sheet steel,
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or
0.020" (0.5 mm) copper.

30" (76.2 cm) minimum clearance between the top of the cooking
platform and the bottom of an uncovered wood or metal cabinet.

IMPORTANT: If installing a range hood or microwave hood
combination above the range, follow the range hood or
microwave hood combination installation instructions for
dimensional clearances above the cooktop surface.

Electrical Requirements

This range is equipped with an electronic ignition system that
works with an 9V DC alkaline battery (not included). See the
“Installing/Replacing Battery” section for instructions on installing
and replacing the battery.

25

⁷⁄₈

"

(65.9 cm)

19

³⁄₄

"

(50 cm)

41

¹¹⁄₁₂

"

(106.6 cm)

A. 18" (45.7 cm) min. clearance upper side cabinet to countertop
B. 13" (33.0 cm) max. upper cabinet depth

C. 20" (50.8 cm) min. cabinet opening width
D. For minimum clearance to top of cooktop, see NOTE.

E. 20

¹⁄₈

" (51.1 cm) min. opening width

F. This shaded area recommended for installation of gas pipe.

G. 3" (7.6 cm) min. countertop space to side wall or other

combustible material

H. 10" (25.4 cm)

I. 5

¹⁄₂

" (14 cm)

J. 4" (10 cm)

K. 2" (5.1 cm)

A

B

C

D

E

F

G

H

I

K

J