MAINTENANCE

86037780 EXTRACTOR 11/21/07

4-3


BRUSH MOTOR REMOVAL


1. Turn off switch and unplug machine.

2. Set the machine in its upright position. Remove

the screws (2) in the back metal cover. Rotate
the cover down and slide back releasing the tab
under the machine from the main frame.


3. Remove the pump box cover. Remove screws

(4) at each leg of the cover.


4. To remove brush motor, position the machine to

have access to the bottom. Remove screws (2)
at the sides of the machine holding the brush
deck pivot axle.


5. Remove screw mounting belt cover and remove

belt cover.


6. Remove the nuts and washers (2) at brush

motor and slide motor forward to reduce belt
tension. Remove belt.


7. Remove pulley by loosening set screw and pull

off shaft.


8. Unplug the brush motor wires from the rectifier

located in the pump mount housing. Also,
remove the ground lug from the stud on the
main frame by removing the nut on the stud.


9. Reverse the process to reinstall the motor. Align

motor pulley with brush pulley. Check belt for
proper belt tension.

PUMP REMOVAL

1. Turn off switch and unplug machine.

2. Set the machine in its upright position. Remove

the screws (2) in the back metal cover. Rotate
the cover down and slide back releasing the tab
under the machine from the main frame.


3. Remove the pump box cover. Remove screws

(4) at each leg of the cover.

4. To remove either pump, loosen the hose clamp

and remove the hose from both ends of the
pump.


5. Remove screws and washers (4) that mount

pump housing.

6. Unscrew the hose fittings from each end of the

pump.

7. Flex the pump mounting housing to remove the

pump.

8. Remove the screw attaching the ground wire to

the pump. Remove the other two wire
connectors attached to the pump.

9. Reverse the process to reinstall the pump.

Advertising