TROUBLESHOOTING

25

PROBLEM: TV Interference

Problem

Solution

Electrical interference from

Add a Ferrite data line

filter inverter.

on to the TV power cord.
This filter is available at
electronic supply stores.

PROBLEM: Low or No Output Voltage

Problem

Solution

Using incorrect type of

Use true RMS reading meter

voltmeter to test output

See "For You Technical

voltage.

Types" Section of this
manual.

PROBLEM: Low Battery Alarm On All The Time

Problem

Solution

Input voltage below

Keep input voltage above

11 volts.

11 volts to maintain

regulation.

Poor or weak battery

Replace battery.

condition.
Inadequate power being

Use lower gauge wire. See

delivered to the inverter

“Wire Cable Gauges”

or excessive voltage drop.

section of this manual.

Keep wire length as short

as possible.

24

TROUBLESHOOTING

Overload LED on

Problem

Solution

Equipment has a high

Turn inverter power switch

start up surge.

OFF (O) and then ON (l)

again until the inverter

powers your appliance.

Repeat as necessary

to get your appliance

"started".

Battery voltage below

Recharge or replace

10 volts.

battery.

Equipment being operated

Use a higher capacity

draws too much power.

inverter.

Inverter is too hot (thermal

Allow inverter to cool.

shutdown mode).

Check for adequate

ventilation. Reduce the

load on the inverter to

rated continuous power
output.