Setting The Controller - Continued

ADVANCED CUSTOMER SETTINGS:

Your appliance can be programmed for High Capacity (HC) or High Efficiency (HE). High Capacity
means the appliance will regenerate less often, but use more salt. High Efficiency will make the
appliance regenerate more often and use less salt. See Specification/Capacity Chart, pg. 25.

1. Hold down SET and CHANGE for 3 seconds to enter advanced customer settings mode.
While SET and CHANGE are being held down, the display should show only the controller
type. After the 3 seconds, the entire screen is lit for a half second, and then "HC" will appear.

2. Pressing and releasing the CHANGE button will toggle the digit display between "HC" and
"HE". Pressing and releasing the SET button will advance programming to the next step.
Default is "HC".

3. The controller will now display "Demand Mode." Each press of the CHANGE button will
switch between "Demand Mode" and "Delayed Mode".

Delayed Mode allows regeneration at a specific time (e.g. at 2 am when less water is being
used.) Demand Mode triggers a regeneration as soon as softening capacity is exhausted.

Pressing and releasing the SET button will advance programming to the next step. Default is
"Demand Mode".

4. "96 Hours" is now displayed. Pressing and releasing the CHANGE button will toggle this
on and off.

If "96 Hours" is selected, the unit will work no more than 4 days without a regeneration.
Note: If there is iron in your water, select this option.

Pressing and releasing the SET button will advance programming to the next step.
Default is for "96 Hours" to be ON.

5. "Gallons X100" is now displayed. Pressing and releasing the CHANGE button will toggle
between "Gallons X100" and "Liters X1000". Choosing gallons sets the controller to English
units, and choosing liters sets it to metric units. Pressing and releasing the SET button will
advance programming to the next step.

6. If "Gallons" was chosen "12" is now displayed. If "Liters" was chosen "24" is displayed.
Pressing and releasing the CHANGE button will toggle between "24" and "12". This controls
the selection of a 12-hour (AM/PM) or 24-hour clock. If 24-hour, 00=midnight.
Default is "12".