Troubleshooting – Windsor E50 User Manual

Page 15

Advertising
background image

TROUBLESHOOTING

ENSIGN 98635 03/26/04

4-4

PROBLEM

CAUSE

SOLUTION

Dead electrical circuit

Check building circuit breaker or fuse box.

Loss of Power

Faulty power cord

Replace

Equipment not grounding

Follow grounding instructions exactly

Receptacle not grounded

Contact an electrician to check building’s wiring

Electrical shock

Internal wiring problem

Have a trained service technician check machine’s
wiring

Worn motor brushes

Replace

Motor worn out

Replace

Vac motor speed varies
or doesn’t run

Faulty switch

Replace

Loose vacuum dome

Center and seal dome over tank

Crack in dome of poor joint

Replace or repair using acrylic plastic cement only

Lint or dirt clogging
vacuum screen

With power off clean screen

Loose cuffs on vacuum
hose

Tighten cuffs turning counterclockwise

Vac motor seals leaking

Replace

Floor tool vac chamber
clogged

Wash out with hose. Pick lint out with a wire

Loss of vacuum

Vac motor, hose, or dome
gasket

Replace

Pump inlet screen plugged

Clean inlet screen

Pump air locked

Press trigger to open valve on cleaning wand to
relieve air

Pump runs no solution

Internal or external
solution line damaged and
leaking

Replace

Internal pump components
wearing out

Replace, see pump kit components (pg 4-3)

Pump runs, loss of
pressure

Check valves in pump
head for particles or cuts in
seals

Take piston from BPR and lubricate with Superlube.
If problem still exists change BPR kit

Unit not plugged in

Connect unit to 3 prong grounded outlet

Pump will not run

Loose wiring

See dealer

Solution hose fitting hard
to connect

Corrosion on fittings.

Clean with steel wool. Soak in acetic acid (white
vinegar). Lubricate lightly with silicone base lubricant.

Carpet not getting clean

Severe soil conditions

Make several passes at right angles to each other.
Use a pre-spray.

Carpet too wet

Over saturation

Adjust solution pressure to lower settings. Make
several passes without spray

Leaving carpet too wet

Check for loss of vac pressure

Too much chemical

Check label for correct solution concentration

Carpet browning

Light carpet with no brown
prevention

Go over carpet with browning prevent only

Solution hose connection

Check for positive connection

Faulty pump

Repair or replace

Faulty floor tool valve

Repair or replace

Solution not flowing
properly

Faulty pump switch

Repair

Advertising