The figure below shows a standard cooker installation fitted with a steel splashback (optional accessory) and
an extraction hood (optional accessory). The model shown is a 100cm Dual Fuel Cooker with a 90cm
Chimney Hood, with the installation requirements and dimensions detailed being similar when installing other
cooker models or when installing a box or glass hood.

9

Extractor Hood Electrical
Supply:
Standard 3 pin socket
located behind steel ducting.

O 125mm Extraction pipe through wall.

O 125mm Flexible Extraction Pipe (not
supplied) connected between extractor flue
outlet & pipe through wall.

Extendable steel ducting
[Minimum height of 450mm to
maximum of 860mm]

The metal filters can be
replaced with carbon filters
(optional extras) thus
eliminating the requirement for
the O 125mm Extraction pipe.

Splashback fixed to wall
through two fixing holes on top
& bottom lips.

Back Trim not on Electric Hob
Models.

Gas connection made on top
RHS of cooker. This can be
moved to the top LHS (Refer to
Fig.5) [Not applicable to Electric
Hob Models]

Gas connection made using
flexible gas line to allow ease of
removal of unit [Not applicable
to Electric Hob Models]

Extractor Hood is fitted to the
wall using the rawl plugs &
screws provided. A
template on the extractor hood
carton details the
position of the fixing holes.

32 Amp Cooker
Switch Box.

Electrical Connection
made on back LHS of
appliance.

(Refer to Fig.4)

300 -
700

260- 280

750

200 -
700

Steel Ducting fixed to wall using supplied
bracket

Note:

Dimension ranges for position of power supply and extraction pipe are applicable for all extractor hood models
when fitting the unit in a standard 8 foot high room.

STANDARD COOKER INSTALLATION