Important, Overview, Universal cup – W & W Manufacturing X3 & X6 User Manual

Page 4: Selecting “ learn “ for universal cup

Advertising
background image

of battery chemistries such as; Lithium Ion, Lithium Polymer, Nickel Cadmium and Nickel Metal Hydride.
Most mechanical shapes can be accommodated with a specially designed battery cup. See battery
Cup description for more information.

FEATURES

Analyzes, condition and charges Nickel Cadmium and Nickel Metal Hydride batteries.

Analyzes and charge lithium Ion and lithium polymer batteries.

Features a single button capable of multifunction and an easy to read display for a user interface.

Auto condition cycle for nickel batteries and life cycle mode for all batteries.

Quick Test (QT), determines the state of a battery, as well as one of two states

Optional thermal printer for status and result printing.

PC program available for more advance user interfacing and graph generation.

Embedded OEM parameters or user defined profiles in “Learn Mode”.

Prime mode, allows one to enable a Li-ion battery to be unlocked at the upper and lower end of
the Li-ion protective circuits range. Enabling Nickel based battery to acquire a charge to enable
the battery to be evaluated by the various modes of the X3 & X6.

OVERVIEW

The W&W Analyzer X3& X6 is a programmable battery tester and battery cycler capable of testing a variety

4

Batt>60% and Batt<60%

*

Universal cup

The Universal cup will allow one to evaluate batteries with different chemistries and cell counts within defined
specifications. The Universal cup has one memory location that can be programed the same as the Learn
Memory location in a standard cup.

During entry into the “Learn Mode”of the Universal cup, Battery Chemistry, Capacity, and the number of Cells

Are prompted for data entry. Follow the Directions below to enter data for the Learn Mode.

Data Range

Chemistry (Lithium Ion, Nickel Cadmium, and Nickel Metal Hydride)
Capacity 100 - 4000 maH

# Of Cells

1-12 NiCd and 1-4 Li-ion

Important:

It is important that when testing

an UNKNOWN BATTERY in the learn mode that
you select the UNKNOWN state as opposed to
GOOD. You can not perform a valid Quick
test or an impedance test with the Universal cup.
One must observe the proper polarity when
connecting the battery to the Universal cup.
Should you connect the battery incorrectly,
you will hair a buzzing sound, reverse the leads.

At this point you may perform all the standard
operations that can be performed in stations; 2
3, 5 and 6 of the X3 and X6.

To change the cup settings for a different battery
or for different parameters for the same battery,
just repeat the Learn mod process again.

.

17

PUSH BUTTON ONCE

Display After “Turn On”

PUSH

PUSH

PUSH

NO ACTION

NO ACTION

ACTION

PUSH

PUSH

PUSH

PUSH

PUSH

SELECTING “ LEARN “ FOR

UNIVERSAL CUP

NO ACTION

NO ACTION

REMOVE BATTERY

BATT STATUS: UNKNOWN OR GOOD

<FUNCTION> TO CHANGE

ENTER THE NEW CHARGE

RATE: 1000 MA

ENTER NEW DIS -CHRG

RATE: C/2

LION 1CELL 1800MAH

CHRG: 1000MA C /:2

LEARN MODE COMPLETE

SELECTED CAPACITY =

1800 MAHR

PASS / FAIL LEVEL =

80% OF CAPACITY

STORING NEW

CONFIGURATION

REMOVE BATTERY

BATTERY TYPE =

LITHIUM ION

CELL COUNT =

2 CELLS

LEARN MODE

SELECTED

INSERT BATTERY

EMPTY

EMPTY

READY

Universal cup.