E series built-in double ovens, Specifications, Installation specifications – Wolf Appliance Company DO30-2F/S User Manual

Page 2: Overall dimensions, Overall width 29, Overall height 50, Overall depth 23, Min inset width 30, Opening height 49, Min inset height 50

Advertising
background image

E Series Built-In Double Ovens

Installation Notes

Wolf E Series built-in ovens may be used in
a standard installation, where the face trim
overlaps stiles and rails, or in a flush inset
installation with the front of the oven flush
with surrounding cabinetry.

Complete installation specifications can be
found on our website, wolfappliance.com.

Unit dimensions may vary by ±

1

/

8

".

5"

(127)

E

28

1

/

2

"

(724)

OPENING WIDTH

4"

(102)

E

E

E

33"

(838)

RECOMMENDED CABINET WIDTH

30"

min (762)

49

5

/

8

"

(1260)

OPENING

HEIGHT

24"

min (610)

OPENING DEPTH

67"

typical

(1702)

ELECTRICAL LOCATION
WITHIN OPENING
APPLIES ONLY TO
CABINETS DEEPER
THAN 24" (610)

Specifications

Overall Width

29

7

/

8

"

Overall Height

50

3

/

8

"

Overall Depth

23

3

/

4

"

Oven Door Clearance

22"

Oven Interior Capacity
(per oven)

4.5 cu ft

Oven Interior Dimensions
(per oven)

25" W x 16

1

/

2

" H x 19" D

Recommended Cabinet Width Standard 30"

Flush Inset 33"

Minimum Cabinet Depth

Standard 24"

Flush Inset 25"

Minimum Base Support

400 lbs

Opening Width

28

1

/

2

"

Min Inset Width

30

3

/

8

"

Opening Height

49

5

/

8

"

Min Inset Height

50

15

/

16

"

Electrical Requirements

240/208 V AC

60 Hz, 50 amp circuit

Electrical Rating

8.9 kW at 240 V
6.7 kW at 208 V

Shipping Weight

466 lbs

Installation
Specifications

Standard Installation

Overall Dimensions

IMPORTANT NOTE: Unless you are using cabinets
deeper than 24" (610) for a standard installation or
25" (635) for a flush inset installation, it is recom-
mended that the electrical supply be placed in an
adjacent cabinet within reach of the conduit.
Choose the location shown in the illustrations that
best suits your installation.

23

3

/

4

"

(603)

BEHIND FRAME

50

3

/

8

"

(1280)

49

1

/

2

"

(1257)

28

1

/

4

"

(718)

29

7

/

8

"

(759)

23

3

/

4

"

(603)

OPEN OVEN DOOR

TOP VIEW

2

5

/

8

"

(67)

22"

(559)

1

1

/

4

"

(32)

1"

(25)

1

7

/

8

"

(48)

1

7

/

8

"

(48)

RIGHT SIDE VIEW

29

7

/

8

"

(759)

INSTALLER

SUPPLIED CABLE

CHANNEL

49

5

/

8

"

(1260)

OPENING

HEIGHT

50

15

/

16

"

min (1294)

FLUSH

INSET

HEIGHT

30

3

/

8

"

min (772)

FLUSH INSET WIDTH

28

1

/

2

"

(724)

OPENING WIDTH

5"

(127)

4"

(102)

E

E

E

E

36"

(914)

RECOMMENDED CABINET WIDTH

33"

min (838)

24"

min

(610)

OPENING

DEPTH

1"

(25)

25"

min

(635)

FLUSH

INSET

DEPTH

7

/

16

"

(11)

7

/

8

"

(22)

ELECTRICAL LOCATION
WITHIN OPENING
APPLIES ONLY TO
CABINETS DEEPER
THAN 25" (635)

67"

typical

(1702)

SIDE VIEW

TOP VIEW

Flush Inset
Installation

Dimensions in
parentheses are in
millimeters unless
otherwise specified.

Advertising