Waterford Precision Cycles Freestanding 70 User Manual

Page 10

Advertising
background image

loading the refrigerator (see Using the Refrigerator
Efficiently, Different Storage Zones section).

Brief Temperature Variation

Brief temperature variation may occur when the
freezer door is open during loading. These varia-
tions will not affect the food and the temperature
will quickly return to its preset value.

Display Brightness Adjustment

There are 3 different options to adjust the bright-
ness of the display;

* 1.8 minimum

brightness

* 2.8

medium brightness

* 3.8

maximum brightness (default setting)

To adjust:

Note: It is recommended to start the quick freeze
function for at least 2 hours before loading the
freezer.

Option “24” Hours

“24” will appear on the display.

Option “48” Hours

“48” will appear on the display.

Quick Cooling

This function is recommended when loading the
refrigerator with a large quantity of food.

The compressor runs continuously until the refriger-
ator compartment’s temperature drops down to 1

o

C

after which the super cooling function is automati-
cally disabled and the normal compressor run cycle
resume to restore the latest set temperature.

button (5) together to activate the function
“SC” will appear on the display and the
blue light will appear.

It is still possible to view the refrigerator compart-
ment current temperature by pressing the

To disable the quick cooling function manually:

button (5) together again.

Cooling Fan

This function allows maintaining the same tempera-
ture on all levels of the refrigerator chamber.

It is switched ON and OFF by pressing the
button (12).

The yellow light (13) is turned on when the function
is activated.

When the cooling fan is not switched on, the natu-
ral circulation of air within the refrigerator chamber
will cause different temperature zones. This is
caused by the cold air sinking to the lowest section
of the chamber. This should be kept in mind when

Press and hold the

press the

button (10) and

button (6) once.

CFL

FREEZE

Press and hold the

press the

button (10) and

button (6) twice.

CFL

CFL

Press the

button (8).

button (10) and the

CFL

COOL

Press the

button (10) and

CFL

COOL

FREEZE

Press and hold the
Press the

button (8) to decrease brightness.

button (9) to increase and the

button (10)

Alarm and Error Codes

Error

Codes

Type

Description

E1

Temperature sensor
fault in refrigerator
chamber

Sensor has been
damaged. Call a quali-
fied technician. The
built-in emergency
program will maintain
an adequate tempera-
ture until the fault has
been removed.

E2

Temperature
sensor fault in
freezer chamber

E4

Door open

The freezer door has
been open for more
than 2 minutes

E5

Temperature in the
freezer chamber is
too high

The temperature
inside the chamber is
exceeding

Interrupting The Alarm

The alarm can be interrupted by opening and clos-
ing one of the doors or by pressing any button on
the control panel for 7-8 seconds.

In case of error E1/E2, the alarm can only be
stopped when the damaged sensor has been
changed.