Whynter T-1A User Manual

Page 7

Advertising
background image

T-1 Version 08/05

7


Appliance Operation (Continued)

cubes until after the four beeps have finished otherwise the appliance will beep
continuously and the cubes may be deposited into the Ice Drawer recess rather
than the Ice Drawer itself. If the appliance does beep continuously ensure the Ice
Cube Drawer is fully in its recess.

The appliance will continue to produce ice cubes at approximately 12 minute
intervals. Some variation in cube size can be expected however such variation
should be minimized once the appliance has stabilized. Variables such as water
temperature and ambient temperature can affect ice cube size.

When the Ice Cube Drawer is full the appliance will detect this and beep 10 times.
The S, M and L lights will flash for 5 minutes and, if the Ice Cube Drawer is not
emptied, the appliance will go into sleep mode. Emptying the Ice Cube Drawer
and replacing it in its recess will re-start the ice making process. If the Ice
Cube Drawer is not emptied the cubes will melt and the water will drain back into
the Water Tank. When sufficient cubes have melted the ice making process will
re-start again automatically.

As water is drawn from the Water Tank the level will drop and eventually the
WATERTANK indicator on the Function Display will turn from green to red or
red/orange indicating that the tank requires topping up. It is not necessary to top
up the tank immediately. The ideal time to top up the tank is a couple of minutes
after the water has stopped being pumped into the water tray. This is because
towards the end of the ice cube production cycle the water tray inverts and any
unfrozen water in the tray drains back into the Water Tank. If the Water Tank is
removed for the purposes of topping up during this period then water will be
deposited into the base of the appliance and then leak onto the surface on which
the appliance is standing.

Topping up an appliance which has been running for a number of cycles the
water level should be approximately 5mm (¼ inch) below the MAX line of the
Water Level Indicator. This is so that the Water Tank does not overflow after
water tray inversion.

The appliance can be stopped at any time by pressing the STOP button on the
Function Display. If this is done the red START indicator will flash.