Wayne 3018 User Manual

Page 16

Advertising
background image

16

Step 14: Install Wired Infrared Safety Sensor Wall Mounting Brackets



Use the following instructions if your opener is
equipped with Wired Infrared Safety Sensors. If
you just installed the Wireless Infrared Safety Sen-
sors go to step 19.



Select a mounting position 5 inches above the floor to
center line of wall bracket. The sending and receiving
units should be mounted inside the door opening to
minimize any interference by the sun. However, the
sensors should be mounted as close to the door track
or inside edge of the door as possible to offer
maximum entrapment protection. It is very important
that both wall brackets be mounted at the same
height for proper alignment.




The brackets may be temporarily mounted to the jamb with a 1” flat
head nail (provided), permanently mount the wall mounting bracket
to both door jambs. In some installations it may be necessary to
attach wooden spacers to the wall to achieve the required
clearance. Expansion bolts (not included) may be required to
attach brackets to walls constructed of materials other than wood
or gypsum.


Step 15: Install Wired Infrared Safety Sensor Wall Mounting Brackets



Attach the “U” brackets to the wall brackets with a
1/4 -20 carriage bolt, washer and hex nut
(provided). Insert the bolt from the inside of the “U”
bracket and hand tighten only at this time.