MAINTENANCE

ADMIRAL 86038230 03/16/07

4-

ARNING:

5

!

W

`

SOLUTION PUMP REPLACEMENT

ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM
THE FOLLOWING REPAIRS.

1. Turn off all switches and unplug the machine.

2. Remove

recovery tank.

3. Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame.

4. Remove solution hoses from fittings in pump.

5. Remove the (2) screws that fasten the pump to the frame.

6.

Reverse process to install pump.

PUMP REPLACEMENT KITS SHURFLO 100 PSI 86026390 PRV NO. (65201)

Bypass Valve Asm

86258830

PRV NO. 84161

Diaphragm

86235100

PRV NO. 29206

Pump Head Replacement

8251040

PRV NO. 65187

86161980

PRV NO. 250-67

Switch Asm

PUMP REPLACEMENT PARTS FOR FLOJET 100 PSI PRIOR TO SERIAL # *

Diaphragm

86235120

PRV NO. 29219

Motor

86247360

PRV NO. 53245

Valve Asm

86258860

PRV NO. 84166

Pump Head

86251090

PRV NO. 65204