Side burner troubleshooting, Side burner maintenance, Problem check cure – weber 42092 User Manual

Page 43

Advertising
background image

D-10

Problem

Check

Cure

Side Burner does not light.

Flame is low in HIGH position.

Push button ignition does not
work.

Is gas supply off?

Turn supply on.

Is the fuel hose bent or kinked?

Straighten hose.

Does burner light with a match?

If match lights burner, checkigniter
(see below).

Side Burner maintenance

ƽ WARNING: All gas controls and supply valves
should be in the OFF position.

Make sure wire is connected between igniter and
electrode. Check that igniter lock nut is tight.
Note: If the igniter works loose, carefully tighten the
igniter lock nut with an adjustable wrench or pliers.
Adjust igniter electrode to burner. Gap should be 1/8 to
3/16 inch from tip of electrode to burner. Spark should
be a white/blue color, not yellow.

1) Igniter Wire
2) Venturi/Burner
3) 1/8 to 3/16 inch gap between electrode and burner

Side Burner Troubleshooting

(3)

Side Burner Grate

Side Burner Cap

Side Burner Ring & Head

Igniter Electrode

Control Knob

(2)

(1)