Figure 11

27

View from behind
cooking box

Wing nuts

Figure 10

Guide screw

Crossover tube

Figure 12

Figure 9

e) Remove the manifold bracket and unscrew the two

wing nuts that hold the manifold to the cooking box.
Pull the manifold and valve assembly out of the
burners and carefully set it down. Figure 10.

d) Unlatch the Spider Stopper Guards and remove.

Figure 9.

f)

Slide the burner assembly out from under the guide
screw and washer in the corners of the cooking box.
Figure 11.

g) Lift and twist the burner assembly slightly, to separate

the crossover tube from the burners. Figure 12.
Remove the burners from the cooking box.

i)

Reinstall the Spider Stopper Guards. Slightly rotate
the Spider Stopper Guards so that the seams are in
line with the Venturi fins. There should be no gaps in
the seams or in the fit around the burners and valves.
Figure 14.

Venturi fin

Figure 14

Check fit
around valve

Check fit around burner

h) To reinstall the burners, reverse steps c) through g).

ƽ

CAUTION: The burner openings must be positioned

properly over the valve orifices. Figure 13a.

Check proper assembly before fastening manifold in place.
Figure 13b.

Figure 13

Valve

Burner

(a)

(b)