603-750-0 pg4-1, Maintenance, Troubleshooting – Windsor PJ2AIE User Manual

Page 9: Wiring diagram

Advertising
background image

MAINTENANCE

86037500 PJ2A 03/04/08

4-1

DAILY MAINTENANCE

1. Vacuum unused cleaning solution from solution tank into recovery bucket.
2. Flush two gallons of clean water through pumping system of extractor, PILEJOGGER and hand tools. Twice

a month, flush a vinegar solution (one quart white vinegar to two gallons water) or browning prevent solution
(mixed as directed) through extractor and PILEJOGGER. This will minimize buildup of alkaline residue in the
system.

3. Remove carpet lint from brush fibers and underside of brush housing. Flush out with water.
4. Check for carpet lint buildup in vac shoe. Clean out and flush with water.
5. If spray jets become clogged, remove from manifold, wash and blow-dry to remove obstruction. Do not use

pins, wires, etc. to clean jets as this could destroy spray pattern.

6. Apply silicone lubricant to quick-disconnect fittings.

TROUBLESHOOTING

PROBLEM.

CAUSE SOLUTION

No power to brush

Dead electrical circuit

Check building circuit breaker or fuse box

Faulty switch

Replace

Faulty electrical cable

Replace

Brush motor speed
varies or doesn’t run

Faulty motor

Replace

Faulty switch

Replace

Loss of vacuum

Loose cuff on vac hose

Tighten cuffs (turn counterclockwise)

Vac chamber plugged

Wash out with hose. Pick lint out with wire.

Broken vac hose

Replace

Solution hose quick
disconnects hard to
insert

Corrosion on fittings

Clean fitting by soaking in vinegar solution, lubricate
lightly with silicon lube

Solution won’t shut off

Faulty solution valve

Repair or replace

Clogged spray jets

Corrosion

Clean with steel wool and vinegar solution; wipe dry
after each use.

Carpet not clean

Severe soil conditions

Make more than one pass at right angle to first pass.
Prespray.

Carpet too wet

Loss of vacuum

Check vac system for leaks