Т³гж 6, Step – Well Traveled Living 60255 User Manual

Page 6

Advertising
background image

Creates a
generous zone
of comfort!

1500W
Quartz Halogen
Lamp

SAFE for INDOOR
Applications too!

Uses standard
120V household
current

45 degrees
angle of heat
spread

10ft

19ft

10.8ft

84"

Min head unit

clearance from

combustibles

10" wall and

12" ceiling

For optimal performance and safety concerns,we HIGHLY RECOMMEND that the Infrared Heater

Head be operated at a min. of 84''ht. with a 45-55 degree angle of operational spread.

To Adjust The IR Head Unit:
Swivel head unit up or down to desired position. The head unit must be at a 45-55
degree angle for optimal operation and output.There should only be a moderate
amount of tension to maintain the swivel bracket. If it becomes too loose, tighten
hex nuts and bolts at swivel points on head unit bracket.
The adjust angle of Head Unit is less than 45 degree.

Note:Be sure electrical cord is grouded and positioned away from head unit.

Before plug your Infrared Heating System, adjust the head unit
angle as desired. Do NOT touch the head unit during operation
or for 30 minutes AFTER unplug.
The head units GETS VERY HOT!

Refer to coverage area in Fig. 7 for best positioning location and heat
spread/coverage.

Step

1

Step

2

The infrared electric heating system comes equipped with a heavy duty ,
16/3 gauge wire and grounded plug. This appliance must be used with an
outlet that has been installed and grounded in accordance with all local
codes and ordinances. Makes sure that the heater is connected to an
outlet having the same configuration as the plug shown in Fig. 8. Do NOT
use an adapter with this product. Check with a licensed electrician if the
grounding instructions are not understood completely or if the wall outlet
does not match the plug.

Grounding instructions
The instruction manual of grounded heaters shall include the following or
equivalent wording: (In the case of a heater rated for a nominal 120 voilts.)
This heater is for use on 120 voits.The cord has a plug as shown at Ain
Figure 65.1 An adapter as shown at C is available for connecting three-blade
grounding-typeplugs to two-slot receptacles.The gree grounding lug extending
from the adapter must be connected to a permanent ground such as a properly
grounded outlet box.The adapter should not be used if a three-slot grounded
receptacle is available.

Always UNPLUG unit when not in use!

Your infrared electric heating system is ready to enjoy.Plug the appliance in and begin
enjoying the warmth!

* When using outdoors, we recommend using a certified GF I(Ground
Fault Interrupt)outlet to protect against electrical shock.
* Ensure that the heater mounting bracket is SECURELY fastened to the
wall,patio overhang or house eave.
* Route electrical cable AWAY from main body of heater which gets very hot.
* Do NOT cover or obstruct the main body of the heater during use.
* All installations must be in accordance with I.E.E. safety regulations or
equivalent. If you are unsure, consult an electrical service professional.
* Avoid the use of extension cord with this appliance.If one is used,
it MUST be at least a 14/3 wire, grounded cord, 50ft max. length.

* Do not place any objects such as furniture, papers, clothing or curtains
closer than 3 ft to the front and the side of the heater.

NOTE: your IR Heater main body, electrical components & bracket are fully
factory assembled. Do NOT attempt to service or disassemble without proper
instructions.

This appliance MUST be grounded.

Step

3

Advertising