York SUNLINE PLUS D2EG 048 User Manual

York Conditioners

Advertising
background image

GENERAL

YORK Model DEG units are single package air conditioners with

gas heat designed for outdoor installation on a rooftop or a slab.
The units are completely assembled on rigid, permanently

attached base rails. All piping, refrigerant charge, and

electrical wiring is factory-installed and tested. The units

require only electric power, gas piping and duct connections

at the point of installation.
The gas-fired heaters have aluminized steel tubular heat

exchangers and spark ignition with intermittent pilot.
This appliance is not to be used for temporary heating of

buildings or structures under construction.

INSPECTION

As soon as a unit is received, it should be inspected for possible

damage during transit. If damage is evident, the extent of the

damage should be noted on the carrier's freight bill. A separate

request for inspection by the carrier's agent should be made in

writing. Refer to Form 50.15-NM for additional information.

REFERENCE

Additional information on the design, installation, operation

and service of this equipment is available in the following

reference forms:

55.70-N1

-General Installation

55.70-N2

-Pre-start & Post-start Check List

530.18-N1.2V

-Economizer Accessory

530.18-N1.13V -Man. Outdoor Air Damper Accy 0-35%

530.18-N1.14V -Man. Outdoor Air Damper Accy 0-100%

530.18-N1.12V -Motorized Outdoor Air Damper Accy.

530.18-N1.8V

-Coil Guard

530.18-N2.11V -Low NOx Accessory

530.18-N8.2V

-High Altitude Accy. (Natural Gas)

530.18-N8.3V

-High Altitude Accy. (Propane)

530.18-N8.4V

-Gas Piping Accessory

530.18-N8.12V -Propane Conversion Accessory

690.15-N25V

-Low Ambient Accessory

Renewal Parts:

Refer to Parts Manual for complete listing of replacement

parts on this equipment.

All forms referenced in this instruction may be ordered from:

Standard Register

Toll Free Tel.: 877-318-9675

Fax: 877-379-7920

APPROVALS

Design certified by CGA and UL listed as follows:

1. For use as a forced air furnace with cooling unit.

2. For outdoor installation only.

3. For installation directly on combustible flooring or, in the U.S.A.,

on wood flooring or Class A, B, or C roof covering material.

4. For use with natural gas and/or propane (LP) gas.

Not suitable for use with conventional venting systems.

®

SUNLINE PLUS

GAS / ELECTRIC

SINGLE PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTION

Supersedes: 035-14832-002-A-0302

035-14832-003-A-0204

MODELS D2EG 048 & 060 and D3EG 036

(11 SEER)

Installer should pay particular attention to the words: NOTE, CAUTION and WARNING. Notes are intended to clarify or make

the installation easier. Cautions are given to prevent equipment damage. Warnings are given to alert installer that personal in-

jury and/or equipment damage may result if installation procedure is not handled properly.

FOR YOUR SAFETY

Do not store or use gasoline or

other flammable vapors or liquids

in the vicinity of this or any other

appliance.

If you smell gas:

1. Open windows

2. Don't touch electrical switches.

3. Extinguish any open flame.

4. Immediately call your gas supplier.

CAUTION

THIS PRODUCT MUST BE INSTALLED IN STRICT COMPLIANCE WITH THE ENCLOSED INSTALLATION INSTRUC-

TIONS AND ANY APPLICABLE LOCAL, STATE, AND NATIONAL CODES INCLUDING, BUT NOT LIMITED TO, BUILDING,

ELECTRICAL, AND MECHANICAL CODES

WARNING

INCORRECT INSTALLATION MAY CREATE A CONDITION WHERE THE OPERATION OF THE PRODUCT COULD

CAUSE PERSONAL INJURY, PROPERTY DAMAGE AND/OR DEATH.

WARNING

DE-ENERGIZE THE ELECTRICAL POWER AND TURN OFF THE GAS SUPPLY TO THE UNIT BEFORE ATTEMPTING TO

INSPECT, REPAIR OR PERFORM MAINTENANCE TO THE UNIT.

Advertising
This manual is related to the following products: