Installation – Yukon Advanced Optics Oil Furnace User Manual

Page 15

Advertising
background image

Installation

FIG. 9

FIG. 10

OIL BURNER INSTALLATION
Model LWO-112 burner has a (140,000 BTU input)

1.00 G.P.H. 80 degree H nozzle installed at the factory.

Model LWO-168 burner has a (189,000 BTU input)

1.35 G.P.H. 80 degree H nozzle installed at the factory.

Install burner as follows:
1. Make sure hole in side of pyrolite chamber lines up

with hole in the end of the blast tube. (See Fig. 9)

2. Install drip shield (shipped in blower compartment)

over studs. Place gasket (packed in burner box) over
drip shield. (Fig. 10)

3. Remove nuts from burner mounting studs on face of

furnace.

4. Place gasket (packed on burner box) over studs and

install drip-shield. (Shipped in blower compartment.)

5. Insert burner tube into furnace. The burner mounting

flange should be tight against the drip-shield and
furnace front.

6. Install mounting nuts and tighten.

GAS BURNER INSTALLATION
Model LWG-112 A 7/32" dia. orifice has been installed

at the factory. (140,000 BTU input - nat. gas). To
convert to LP gas, see manufacturers instructions
packed with the burner.

Model LWG-168 A "F" (.257 dia.) orifice has been

installed at the factory (189,000 BTU input - nat. gas).
To convert to LP gas, see manufacturers instructions
packed with burner.

Install burner as follows:

1. Make sure hole in side of pyrolite chamber lines up

with hole in the end of the blast tube. (See Fig. 9)

2. Remove nuts from burner mounting studs on face of

the furnace.

3. Install drip shield (shipped in blower compartment)

over studs. Place gasket (packed in burner box) over
drip shield. (Fig. 10)

4. Assemble mounting flange over burner blast tube (flat

surface away from burner housing). Do not tighten
clamping screws.

5. Insert burner tube into furnace. Align holes in

mounting flange over studs on furnace. Replace nuts
removed in step 2 above and tighten.

6. Insert burner so that burner housing is tight against

mounting flange (end of blast tube should be flush
with inside of pyrolite chamber). Level burner and
tighten clamping screws.

Drip
Shield

CUT AWAY VIEW

BURNER COMBUSTION CHAMBER

Burner

Blast Tube

Pyrolite Liner

In combustion

Chamber

15

Advertising