Connection of grounding and battery systems – Xantrex Technology RV2012 User Manual

Page 22

Advertising
background image

Xantrex RV Series Inverter/Charger Owner’s Manual

17

Connection of Grounding and Battery Systems

The following diagram outlines proper connections for the RV Series inverter/chargers. Several
points of caution are:

DO NOT connect the battery negative (-) terminal to the vehicle chassis ground.

DO NOT connect the DC load negative to the battery negative (-). Connect only to the chassis

ground terminal on the inverter or to the vehicle chassis.

+

+


+

G

RV Series

Inverter

DC Load

Distribution Panel

Battery

Internal shunt connection

Optional

Vehicle chassis

Vehicle chassis

ground (green)










Connect DC loads to Vehicle
Chassis or optionally to the
Inverter’s Vehicle Chassis Ground
Terminal (Green). Do not connect
DC loads to battery negative (-)

Do NOT connect battery
negative to vehicle chassis
or vehicle chassis ground.
Terminal connection to
chassis ground is made
inside the inverter.

Advertising
This manual is related to the following products: