Features and Specifications
Features and Functions

12

Operating Manual for RS-232 for XPD Series Power Supply

Features and Functions

Features

•

16-bit programming and readback of voltage and current

•

Programmable soft limits for voltage and current

•

Programmable over voltage protection with reset

•

Easy-to-use, self-documenting command set

•

Standardized commands for complete communication with any of the supplies

in the system

•

User-programmable isolated fault, polarity, isolation, and auxiliary, user-defined

output signals.

•

LED status signals: error, address, remote/local operation, and over voltage

protection.

•

Foldback in CV or CC mode with reset

•

Software calibration

Programmable

Functions

•

Output voltage and current

•

Soft limits for voltage and current

•

Over voltage protection

•

Output enable/disable

•

Maskable fault interrupt

•

Hold and trigger

•

Output relay signals

Readback

Functions

•

Actual voltage and current

•

Voltage and current settings

•

Soft voltage and current limits

•

Over voltage protection setting

•

Present and accumulated power supply status

•

Programming error codes

•

Fault codes

•

Power supply model and software version identification