Maintenance – Zenoah EB4400 User Manual

Page 13

Advertising
background image

FUEL FILTER

• A clogged fuel filter may cause poor

acceleration of the engine. Check
periodically to see if the filter is clogged
with dirt. The filter can be taken out of the
fueling port using a small wire hook.
Disconnect the filter assembly from the fuel
pipe and unhook the retainer to
disassemble it. Clean the components with
gasoline.

SPARK PLUG

• The spark plug may gather carbon deposits

on its firing end with reasonable use.
Remove and inspect the spark plug every
25 hours and clean the electrodes as
necessary with a wire brush. The spark gap
should be adjusted to .025 in (0.6~0.7mm).

• Plug manufacturers recommend replacing

the plug twice a year to avoid unexpected
plug failure in a job.

REPLACEMENT PLUG IS A CHAMPION
RJ6C.

• Note that using any spark plugs other than

those designated may result in the engine
failing to operate properly or in the engine
becoming overheated and damaged.

• To install the spark plug, first turn the plug

until it is finger tight, then tighten it a
quarter turn more with a socket wrench.

IMPORTANT

• Make sure that the engine has stopped

and is cool before performing any
service to the blower. Contact with
rotating blower fan or hot muffler may
result in a personal injury.

AIR CLEANER

• Never operate the blower without an air

filter or with a deformed or broken filter
element.

• C h e c k the air cleaner every 25 hours

of use or more frequently if used under
dusty conditions. A clogged air filter
may increase fuel consumption while
cutting down the engine power. Never
operate the blower without the air filter
or with a deformed filter element
because unfiltered dusty air will quickly
ruin the engine.

CLEANING AIR FILTER:
1.Remove the air cleaner cover by pulling

the tab on bottom and take out the filter
element.

2.Use neutral detergent and warm water to

clean the filter element. After cleaning, air
dry the element completely and moisten
with a small amount of motor oil.

3.Place the filter element into the air cleaner

housing and press the cover against the
housing until it clicks. Never forget to
attach the screen. If the screen is not
attached, the cleaner will not seal properly
and the dusts come into the cylinder.

WARNING