Table 2-1 Troubleshooting reference

Problem

Possible Cause

Solution

XADC will
not run

Cables are loose

Output fuses are
damaged or not
installed

AC input breaker open

Short circuit in one or
more of the load
circuits

Internal temperature
too hot

Something may be
preventing the fan
from turning. The unit
has a safety shutoff in
this situation.

Check DC and AC connections

Check output fuses

Check AC input breaker

Remove load fuses one by one until
XADC output voltage recovers,
re-install load fuses one by one to
find faulty load circuit(s)

Check that the XADC has sufficient
ventilation. Allow the XADC to cool
down and restart.

Ensure that nothing is obstructing
the fan operation.

Towable-OEM-40-60-80A.book Page 6 Monday, March 5, 2007 12:15 PM