Specifications, Model code – Z-Com SRZ IMS01T05-E2 User Manual

Page 2

Advertising
background image

®

RKC INSTRUMENT INC.

The first edition:

JUN. 2006 [IMQ00]

The second edition: DEC. 2006 [IMQ00]

HEADQUARTERS: 16-6, KUGAHARA 5-CHOME, OHTA-KU TOKYO 146-8515 JAPAN

PHONE: 03-3751-9799 (+81 3 3751 9799)

E-mail: [email protected]

FAX:

03-3751-8585 (+81 3 3751 8585)

DEC. 2006

Modbus is a registered trademark of Schneider Electric.

The name of each programmable controller (PLC) means the products of each manufacturer.

Company names and product names used in this manual are the trademarks or registered

trademarks of the respective companies.

3.3 Contents of the Communication Port

The contents of the modular connector signal are all the same from COM. PORT1 to COM. PORT4.

RS-422A

RS-485A

Pin No.

Signal name

Symbol

Pin No.

Signal name

Symbol

1

Receive data

R (A)

1 Send/receive

data

T/R

(A)

2

Receive data

R (B)

2

Send/receive data T/R (B)

3 Signal

ground SG

3 Signal

ground SG

4

Send data

T (B)

4

Unused

5

Send data

T (A)

5

Unused

6 Signal

ground SG

6 Signal

ground SG

The six-pin type modular connector should be used for the connection to the Z-COM
module. (Recommended manufacturer and model: Hirose Electric, TM4P-66P)

3.4 Example of Connection to PLC

Up to four SRZ units can be multi-drop connected to one PLC communication port.
Customer is requested to prepare a communication cable fit for the Z-COM to be connected by the PLC.

Programmable
controller (PLC)

SRZ unit 1

SRZ unit 2

Connected to

COM. PORT3

Connected to

communication port

Connected to
COM.PORT3

Connected to
COM.PORT4

W-BF-02*

SRZ unit 3

(4 units maximum)

W-BF-01*

* Communication cable (RKC product)

is sold separately.

If communication errors occur frequently due to the operation environment or the
communication distance, connect termination resistors to the Z-COM module and
the other party unit.
For termination resistor of Z-COM modules, see 3.6

Z-COM Module Termination

Resistor.
For the termination resistor of PLC side, see the PLC Instruction Manual.

RS-422A

MITSUBISHI MELSEC series

1

R (A)

R (B)

SG

T (B)

T (A)

SG

2

3

4

5

6

RS-422A

SDB

SDA

SG

RDB

RDA

(

−)

(+)

(

−)

(+)

Shielded twisted pair wire

Paired wire

Z-COM module

COM. PORT3

PLC MITSUBISHI

MELSEC series

(Modular connector)

When preparing a cable of connecting the computer link module belonging to the
MITSUBISHI MELSEC series to our Z-COM module, cross each pair of wires the A
and B terminal positions on their terminal boards are not symmetrical.

OMRON SYSMAC series

1

R (A)

R (B)

SG

T (B)

T (A)

SG

2

3

4

5

6

SDB

SDA

SG

RDB

RDA

RS-422A

(

−)

(+)

(

−)

(+)

Shielded twisted pair wire

Paired wire

Z-COM module

COM. PORT3

OMRON PLC

SYSMAC series

(Modular connector)

RS-485

MITSUBISHI MELSEC series

SDB

SDA

SG

RDB

RDA

*R

RS-485

1

2

3

4

5

6

T/R (A)

T/R (B)

SG

SG

(

−)

(+)

PLC MITSUBISHI

MELSEC series

Shielded twisted

pair wire

Paired wire

Z-COM module

COM. PORT3

(Modular connector)

*R: Termination resistor

(PLC side)

3.5 Example of Connection to the Host Computer

Up to 16 SRZ units can be connected to a host computer communication port. The communication
cable must be provided by the customer.

SRZ unit 1

SRZ unit 2

Connected to
COM.PORT1

RS-232C/RS-422A converter

COM-A (RKC product)

W-BF-02*

Host computer

Connected to

communication

connector

Connected to
COM.PORT1

Connected to
COM.PORT2

W-BF-28*

Connected to
COM.PORT1

Connected to
COM.PORT2

W-BF-02*

SRZ unit 3

(16 units maximum)

RS-422A

RS-232C

* Communication cable (RKC product)

is sold separately.

If communication errors occur frequently due to the operation environment or the
communication distance, connect termination resistors to the Z-COM module and
the other party unit.

For termination resistor of Z-COM modules, see 3.6 Z-COM Module Termination
Resistor.

For the termination resistor of PLC side, see the PLC Instruction Manual.

RS-422A

When the interface of host computer is RS-422A

1

R (A)

R (B)

SG

T (B)

T (A)

SG

T (A)

T (B)

SG

R (A)

R (B)

2

3

4

5

6

RS-422A

(

−)

(+)

(

−)

(+)

Shielded twisted pair wire

Paired wire

Host computer

Z-COM module

COM. PORT1

(Modular connector)

When the interface of host computer is RS-232C (RS-232C

RS-422A)

When the interface of host computer is RS-232C, connect the RS-232C/RS-422A converter
between the host computer and the Z-COM.

COM

Host

computer

Z-COM

RS-232C/RS-422A converter

COM-A (RKC product)

RS-422A

RS-232C

D-SUB 9P
connector

Connected to
COM. PORT1

Connected to
COM. PORT2

Connected to

communication

connector

W-BF-28*

W-BF-02*

Connected to
COM. PORT1

*

Communication cable (RKC product) is

sold separately.

When the host computer has a USB connector

When the host computer has a USB connector, connect the USB communication converter between
the host computer and the Z-COM module.

Host computer

USB communication

converter COM-K

(RKC product)

Connected to USB

port of a personal

computer

USB cable

(COM-K accessory)

Connected to

USB connector

of COM-K

The termination

resistor is built

in to the

COM-K.

RS-422A

1

SG

2

4

3

5

T (A)

T (B)

Shielded twisted

pair wire

Z-COM module

COM. PORT1

(Modular connector)

1

R (A)

R (B)

SG

T (B)

T (A)

SG

2

3

4

5

6

R (A)

R (B)

Paired wire

(

−)

(+)

(

−)

(+)

Loader communication

Connect a USB communication converter between the host computer and the Z-COM module.

Host computer

USB communication converter

COM-K (RKC product)

Connected to

USB port of a

personal computer

Connected to

USB connecter

The termination
resistor is built in
to the COM-K.

COM

Loader communication cable
(W-BV-01)

[Option]

Connected to loader

communication connector

of the Z-COM module

Connected to

loader

communication

connecter

USB cable (COM-K accessory)

3.6 Z-COM Module Termination Resistor

If communication errors occur frequently due to the operation environment or the communication
distance, connect termination resistors to the Z-COM module and the other party unit.

When multidrop connected,

connect a termination resistor to

the Z-COM module at the farthest

end of the communication line.

• When the COM. PORT1 is used:

Insert the termination resistor to COM. PORT2.

W-BW-01 (For RS-485)
W-BW-02 (For RS-422A)
[120

Ω 1/2

W]

• When the COM. PORT3 is used:

Insert the termination resistor to COM. PORT4.

Termination resistor connector

(Sold separately)

4. SPECIFICATIONS

PLC communication

Interface:

Base on RS-422A, EIA standard
Base on RS-485, EIA standard

Protocol:

• MITSUBISHI MELSEC series special protocol (type 4)

− A compatible, 1C frame, ACPU common command (WR/WW)

(A series, FX2N/FX2NC series or FX3U/FX3UC series)

− A compatible, 1C frame, AnA/AnUCPU common command (QR/QW)

(AnA/QnA series, Q series)
D register, R register, W register, ZR register

• OMRON SYSMAC series special protocol

− C mode command (RD/WD)

DM register, EM register (Specify the bank No. +10),
EM register (Specify the current bank)

Communication speed: 4800 bps, 9600 bps, 19200 bps, 38400 bps
Maximum connections: Four SRZ units per communication port of PLC
Usable PLC type:

• MITSUBISHI MELSEC series

− Computer link unit

AJ71UC24, A1SJ71UC24-R4, A1SJ71C24-R4, etc.
The unit which AnA/AnUCPU common command (type 4) can use.

− Serial communication unit

AJ71QC24N, A1SJ71QC24N, QJ71C24, etc.
The unit which AnA/AnUCPU common command (type 4) can use.

− Adapter

FX0N-485ADP, FX2NC-485ADP, FX3U-485ADP

− Expanded function board

FX2N-485BD, FX3U-485-BD

• OMRON SYSMAC series

− High-order link unit

C200H-LK202-V1, C500-LK203, C120-LK202-V1
(SYSMAC C series), etc.

− CPU unit with a built-in communication port

CPU unit of SYSMAC CS1 series and CJ1 series

− Serial communication board

CS1W-SCB41 (SYSMAC CS1 series),
CJ1W-SCU41 (SYSMAC CJ1 series), etc.

Host communication

Interface:

Base on RS-422A, EIA standard
Base on RS-485, EIA standard

Protocol:

RKC communication or Modbus-RTU

Communication speed:

4800 bps, 9600 bps, 19200 bps, 38400 bps

Maximum connections:

Sixteen SRZ units per communication port of Host computer

General specifications

Power supply voltage:

24 V DC

Power supply voltage range:

21.6 V to DC 26.4 V DC
[Including power supply voltage variation]

Current consumption:

30 mA max.

Rush current: 10 A or less

Allowable ambient temperature:

−10 to +50 °C

Allowable ambient humidity:

5 to 95 %RH
(Absolute humidity: MAX.W.C 29.3 g/m

3

dry air at 101.3 kPa)

Installation environment conditions: Indoor use

Altitude up to 2000 m

Weight:

Approx. 110 g

Standard

Safety standard: UL:

UL61010-1

cUL: CAN/CSA-C22.2 No. 61010-1

CE marking:

LVD: EN61010-1

OVERVOLTAGE CATEGORY II, POLLUTION DEGREE 2,

Class II (Reinforced insulation)

EMC: EN61326

C-Tick:

AS/NZS CISPR11 (equivalent to EN55011)

5. MODEL CODE

Z - C O M - A -

(1) (2) (3) (4) (5) (6)

Code (4) to (6) are for quick start

codes to specify software configurable

settings. If not specified, these codes

will not be printed on labels and all

settings will be factory default.

(1) Communication 1 (COM. PORT1, COM. PORT2)

4: RS-422A

5: RS-485

(2) Communication 2 (COM. PORT3, COM. PORT4)

4: RS-422A

5: RS-485

(3) Quick start code (Communication protocol selection)

N*: No quick start code (Configured as factory default)
1: Specify quick start code 1

(4) Communication 1 protocol (COM. PORT1, COM. PORT2) [Quick start code 1]

No code: No specify quick start code
1: RKC

communication (ANSI X3.28)

2: Modbus

(5) Communication 2 protocol (COM. PORT3, COM. PORT4) [Quick start code 1]

No code: No specify quick start code
1: RKC

communication (ANSI X3.28)

2: Modbus
3:

MITSUBISHI MELSEC series special protocol (PLC communication)
AnA/AnUCPU common command (QR/QW)

(AnA/QnA series, Q series)

4:

OMRON SYSMAC series special protocol (PLC communication)

5:

MITSUBISHI MELSEC series special protocol (PLC communication)

ACPU common command (WR/WW)

(A series, FX2N/FX2NC series or FX3U/FX3UC series)

(6) The number of the correspondence channels (Only PLC communication)

No code: No specify quick start code
A: 16

CH

B: 32

CH

C: 48

CH

D: 64

CH

* F

actory set value when there is not specification of quick start code:

Communication 1/communication 2

RKC communication

The number of the correspondence channels: 64 CH

COM. PORT1

Communication 1

Communication 2

COM. PORT3

COM. PORT2

COM. PORT4

Z-COM module internal block diagram

The Z-COM module’s

COM.PORT is internally

connected.

Two systems are used

for communication.

1

6

Modular connector
Pin number

Communication

port
COM. PORT1

COM. PORT2

Communication 1
Connector for Host
computer or Operation
panel connection

[RS-422A/RS-485]

Communication 2
Connector for PLC, Host
computer or Operation
panel connection

[RS-422A/RS-485]

Communication

port
COM. PORT3

COM. PORT4

Advertising