Electrical connections, Supply cable specifications – Zanussi ZCE 700 User Manual

Page 26

Advertising
background image

26

Electrical connections

Any electrical work required to install this hob

should be carried out by a qualified electrician

or competent person, in accordance with the

current regulations.

THIS COOKER MUST BE EARTHED.

The manufacturer declines any liability should these

safety measures not be observed.

This cooker is designed to be connected to a 230-

240V 50Hz AC electrical supply.

Before switching on, make sure the electricity supply

voltage is the same as that indicated on the hob rating

plate. The rating plate is located on the bottom of the

hob. A copy is attached on the back cover of this book.

The cooker is supplied without supply cord. A 3 core

flexible supply cord must be fitted, in accordance with

the specification given in the relevant tables.

1) Loosen the two fixing screws securing the back

protective screen of the cooker, then lift it up

and remove it. This will expose the terminal

block on the right bottom corner.

2) Loosen the two cable clamp screws and lift

the top section of the clamp enough to allow

the cable to be passed through.

3) Connect the red (live) wire to the terminal which

is marked with the letter "L".

4) Connect the black (neutral) wire to the terminal

which is marked with the letter "N".

5) After fitting a green or yellow/green sleeve

over the bare copper wire (earth wire), connect

the exposed end to the terminal which is
marked with the earth symbol

or with the

letter "E" coloured green and yellow.

NOTE:

The earth wire should be about 2 cm. longer

than the live and neutral wires.

6) Secure the cable by means of the clamp

screws and refit the back protective screen.

The cooker should be connected to a double pole switch

with a minimum gap of 3 mm. between the switch

contacts and of a type suitable for the required load in

compliance with the current electric regulations. The

switch should be sited within 2m of the hob and be easily

accessible upon completion of the installation.

The switch must not break the yellow and green earth

cable at any point.

Ensure that the hob supply cord does not

come into contact with surfaces with

temperatures higher than 50 deg. C.

FO 2375

Supply Cable Specifications

Connection Min. size

Cable / flex Fuse

via

Cable/flex type

• Cooker

3 x 6 mm

2

H05 VV-F

30 A

Control

Circuit

For Uk use only

For Europe use only

Min. size Cable/flex Cable / flex type Fuse
3x 2.5 mm

2

H05 RR-F

30 A

H05V2V2-F

F