3. Drill the holes and insert anchor fixings to suit

the wall.

4. Screw the outer grille securely in place. Do

not over tighten screws.

5. Insert the two screw covers in the two fixing

holes in the outer grille.

6a. If wiring from the rear, remove the fan’s

terminal cover and rear entry knockout. Feed

the cable through the rear cable entry.

6b. If wiring from above, remove the fan’s

terminal cover and feed the cable through the

top cable entry.

7. Hold the fan assembly to the inside of the wall

so that the spigot is inserted into the wall
duct.

8. Mark the position of the two fixing holes in the

top left and bottom right corners.

9. Remove the fan assembly, drill the holes and

insert anchor fixings appropriate to the type of
wall.

10. Reposition the cable and fan assembly as

before and screw securely in place. Do not
over tighten screws.


Note: For particularly difficult installations, it is
possible to secure the fan with a combination of screw
and ladder strip fixings.

1. Wire the switch cable into the terminal

connections as shown in:

Fig. E1 for GX6 EC2 / GXC6 EC2 for single
speed operation.

Fig. E2 for GX6 EC2 / GXC6 EC2 for 2 speed
selection operation using a change over switch
(COS).

2. If the fan is wired from above, ensure the

outer sheath of cable is retained in the
labyrinth, see Fig. C.

3. Refit and secure terminal cover.
4. Refit the back draught shutter/grille assembly

by sliding the grille back over the release
catches, the catches will locate and secure
the grille.

5. Switch off the mains electricity supply and

remove fuses.

6. Connect the cable from the isolation switch to

the electrical supply wiring.

7. Replace the fuses and switch on the mains

electricity supply.

For fixed wiring circuits the protective fuse for the
appliances must not exceed 5A.

These fans can either be single speed
operation with a choice between High and Low
at installation, or 2 speed operation when
installed with a change over switch (COS).

The shutters of the GX6 EC2 have a time delay
of up to 1 minute on opening and up to 3
minutes on closing. Activated by operation of
the switch, the delay ensures quiet operation.

For Australia Only :- Warning – Children should
not play with the appliance. Young children and
the infirm should be supervised.

The fan is operated by a remote switch.

Speed selection between High and Low is via a
change over switch (COS) if installed.


The fan is operated by an integral pull cord.

To switch on, pull down the cord and release it.

Repeat to switch off.

Speed selection between High and Low is via a
change over switch (COS) if installed.




Trickle ventilation is equivalent to that provided by an
airbrick or similar device.

1. Remove the back draught shutter/grille

assembly (see “Mounting the fan in the hole”
section).


2. HOLD THE SHUTTER VANES FULLY

OPEN.

3. Push down firmly on the trickle vent catch

until it clicks into position then release the
shutter vanes, see Fig. F. item 6.


4. Pull the trickle vent catch towards you until it

clicks into position.

5. Refit the back draught shutter/grille assembly,

see “Wire the electrical connections” section,
ensuring that the actuator lever is in the “fully
down” position.



A QUALIFIED ELECTRICIAN MUST CARRY OUT
ALL CLEANING.

NOTE: THE FAN WILL CONTINUE TO OPERATE
WITH THE INNER GRILLE REMOVED HENCE IT
MUST BE ISOLATED COMPLETELY FROM THE
MAINS BEFORE ANY WORK IS CARRIED OUT.

1. Before cleaning, isolate the fan completely

from the mains electricity supply. On the
GX6 EC2, allow 3 minutes for the impeller
to stop rotating and the powered shutter
to close. Cleaning on the GXC6 EC2 can
begin once the impeller has stopped
rotating.

2. Remove the back draught shutter/grille

assembly by pressing the release catch
located on the side of the unit with a 6mm
screwdriver or a coin, whilst pulling the grille
forward. To remove the back draught shutter,
lay face down and pull the shutter forwards,
see Fig. G1 and Fig. G2.

Wire the electrical connections

Operating the fan

GX6 EC2

GXC6 EC2

Trickle ventilation

To allow trickle ventilation

To fully close the shutters and stop any back draught

Maintenance

9