QL Plus Series User Guide
rectly under the battery being charged will turn on if the
battery is properly inserted.
The indicators under the battery will allow you to monitor
the charging process per the table below:
Amber
Green
Battery Status
On
Off
Charging
On
Flashing
80% charged (O.K.
to use)
Off
On
Completely
Charged
Flashing
Off
Fault
Important • A fault condition is caused by a problem with the battery.
The charger may indicate a fault because the battery is too hot or cold
to charge reliably. Try to charge the battery again when it returns to
the room’s ambient temperature. If the amber indicator starts flashing
on the second attempt, the battery should be discarded. Always
dispose of batteries in a proper manner as described in Appendix E.
Quad Charger Cycle Times :
Battery
Status
QL 220Plus &
QL 320 Plus
QL 420
Plus
Battery 80%
Charged
1.25 Hrs.
2.5 Hrs.
Battery Fully
Charged
2.5 Hrs.
5 Hrs.
Note • These times are for completely discharged batteries.
Battery packs which are only partially discharged will take
less time to reach their charged state. Batteries which have
reached 80% of their charge capacity may be used, however,
it is recommended that you allow the batteries to reach a full
charge to maintain maximum battery life.
The UCLI72-4 Quad Charger has a safety feature which stops charging