7. The new supply wiring should be terminated

to the GREEN connector block. The correct
locations for the Live, Neutral and Ground
wires are marked on the panel next to the
GREEN socket. The new Black (live) wire
should be terminated in the left hand terminal.
The White (neutral) wire should be terminated
in the center terminal and the Green (ground)
wire should be terminated in the right hand
terminal. (See Pic 24, previous page). Note
that alternative wire colors apply to UK and
Europe.

If the Lighting output is to be used then the
lighting wires should be routed by a qualified
electrician to the orange connector at the bottom
left hand side of the circuit board. A convenient
conduit outlet is provided in the bottom of the
case. The lighting circuit wiring should be rated at
3 Amps. (Pic 25)

The Lighting circuit may be wired to operate a
standard bulkhead light or floodlight of a
maximum rating of 250 watts.

If the Lighting output is to be used, then the
lighting MODE switch No. 6 should be set as
required. The 8-way DIP switch is located at the
top right hand side of the printed circuit board
panel.

(Pic 26)

DIP switch No.6 should be set to the OFF position
if the light is required to switch on when the door
is operated and turn off three minutes from the
last operation.

Switch No. 6 should be switched ON if the light is
required to switch ON when the door is opened
and switch OFF when the door is closed.

If a Remote operation Push Button is to be fitted
then it may be wired to operate in parallel with
the case mounted button, which is connected to
the CYCLE terminals on the printed circuit board.
(Pic 27)

10

Pic 25

Pic 26

Pic 27

Advertising