Instructions for the installer, Something not working, Overall dimensions – Zanussi ZGG649 User Manual

Page 6: Cut out dimensions, Supply connections, Engineer technical data, Symptom, Solution

Advertising
background image

6

OVERALL DIMENSIONS

Width:

580 mm.

Depth:

510 mm.

Height:

88 mm.

Weight:

9,8 Kg.

Instructions for the Installer

CUT OUT DIMENSIONS

Width:

550 mm.

Depth:

470 mm.

Thickness: 40 mm.

Supply Connections

Gas:
RC 1/2 inch (1/2 inch male) Rear right hand
corner

Electric:
230-V 50Hz supply, 3 core flexible cable with
non rewireable plug.

Appliance Gas supply: LPG 30 mbar

Appliance Class: 3

Appliance category: I 3

Engineer technical data

Burner

Nominal Power LPG (Butane "A") Diameter

Feeding

Tap. By-Pass Tap colour Pressure

kW

kCal/h

Nozzle

gh

mbar (*)

Auxiliary (dia. 42 mm.)

0,95

814

50

75

28

Red/Yellow

Semi-rapid (dia. 57 mm.)

1,60

1368

65

126

35

Brown/Black

30

Rapid (dia. 90 mm.)

2,45

2095

80

193

45

Blue/Yellow

(*) 1 mbar = 10 mm. water coloumn.

Something Not Working?

If the appliance is not working correctly, please carry out the following checks before contacting your
local
Service Centre.

SYMPTOM

There is no spark when lighting the gas

The gas ring burns unevenly

SOLUTION

Check that the unit is plugged in and the

electrical supply is switched on

Check that the RCCB has not tripped (if

fitted)

Check the burner cap and crown have been

replaced correctly, e.g. after cleaning.

Check the main jet is not blocked and the

burner crown is clear of food particles.

Check the burner cap and crown have been

replaced correctly, e.g. after cleaning.

If after all these checks, your appliance still
does not operate correctly, contact your local
Service Centre.

Advertising