Troubleshooting, Troubleshooting reference – Xantrex Technology PROWATT SW SW 2000 User Manual

Page 29

Advertising
background image

975-0529-01-01

19

Troubleshooting

Troubleshooting Reference

WARNING: Electrical shock and burn hazard.

Do not dismantle the PROwatt SW Inverter. It does not
contain any user-serviceable parts. Attempting to service
the unit yourself could result in an electrical shock or burn.

Condition

Possible Cause

Solution

E

.

0

.

1

.

Under Voltage (low
input) shutdown

Recharge the battery.
Check cables and
connection if secure.

E

.

0

.

1

.

with persistent low
battery alarm.

Poor DC wiring
and/or poor battery
condition

Use proper cable and
make secure
connections.
Charge the battery or
install a new battery.

E

.

0

.

2

.

Over Voltage (high
input) shutdown

Make sure the
inverter is connected
to a 12 V battery.

E

.

0

.

3

.

Overload shutdown

Reduce the load
within the inverter’s
continuous power
rating.

E

.

0

.

4

.

Heavy load is
connected then AC
output becomes
unavailable.

Over temperature
shutdown

Allow the inverter to
cool off and reduce
the load if
continuous operation
is required.

E

.

0

.

4

.

Normal load is
connected then AC
output becomes
unavailable.

Over temperature
shutdown

Improve ventilation
and make sure the
inverter’s ventilation
openings are not
obstructed.
Reduce the ambient
temperature, if
possible.

Condition

Possible Cause

Solution

PROWatt SW Inverter NA.book Page 19 Wednesday, August 5, 2009 2:24 PM

Advertising