Table 2: capacity ratings - cooling / gas heating, Table 3: sound power ratings, 1 capacity ratings - cooling / electric – York SUNLINE PLUS D1EE036 User Manual

Page 6: Heating, 2 capacity ratings - cooling / gas heating, 3 sound power ratings, Not ari required

Advertising
background image

036-21411-002-A-0204

6

Unitary Products Group

Not ARI required

TABLE 1: CAPACITY RATINGS - COOLING / ELECTRIC HEATING

MODEL

ARI RATINGS

1

NOMINAL ELECTRIC HEAT CAPACITY

2

(kW)

COOLING CAPACITY 80 / 67-95°F

SOUND

RATING

3

(dBels)

MBH

SEER

4

EER

5

240V

480V

600V

DEE036

42.5

11.5

10.10

86.0

5, 7, 10, 15 &

20

7, 10, 15 & 20

10, 15, & 20

DEE048

49.5

11.0

10.0

86.0

5, 7, 10, 15 &

20

7, 10, 15 & 20

10, 15, & 20

DEE060

58.5

11.0

10.05

86.0

5, 7, 10, 15,

20, & 30

7, 10, 15, 10,

& 30

10, 15, 20 &

30

1.

Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240.

2.

Heaters are available as accessories - all with single point power supply

3.

Rated in accordance with ARI Standard 270.

4.

SEER =Seasonal Energy Efficiency Ratio - the total cooling output in BTU’s during a normal annual usage period for cooling
divided by the total electric power input in watt-hours during the same period.

5.

EER = Energy Efficiency Ratio - the cooling capacity in BTU’s per hour (BTUH) divided by the power input in watts at any given
set of rating conditions, expressed in BTUH per watt (BTUH/watt).

TABLE 2: CAPACITY RATINGS - COOLING / GAS HEATING

MODEL

ARI RATINGS

1

GAS HEAT CAPACITY

COOLING CAPACITY 80 /

67-95°F

SOUND

RATING

2

(dBels)

INPUT

(MBH)

OUTPUT

(MBH)

AFUE

3

(%)

S.S.E.

4

(%)

TEMP.

RISE

(°F)

GASE LINE SIZE

(in. O.D.)

MBH

SEER

5

EER

6

DEG036N040

42.5

11.5

10.1

86

50

40

80.9

81.6

15-45

1/2

DEG036N079

42.5

11.5

10.1

86

100

79

80.5

80.8

40-70

1/2

DEG048N060

49.5

11.0

10.0

86

75

59

80.9

81.6

25-55

1/2

DEG048N099

49.5

11.0

10.0

86

125

99

80.3

80.6

45-75

1/2

DEG060N079

58.5

11.0

10.05

86

100

79

80.5

80.8

25-55

1/2

DEG060N099

58.5

11.0

10.05

86

125

99

80.3

80.6

35-65

1/2

1.

Ratings are in accordance with ARI Standard 210.

2.

Sound ratings are in accordance with ARI Standard 270.

3.

AFUE = Annual Fuel Utilization Efficiency - determined in accordance with DOE test procedure.

4.

S.S.E. = Steady State Efficiency (Percent Output).

5.

SEER =Seasonal Energy Efficiency Ratio - the total cooling output in BTU’s during a normal annual usage period for cooling
divided by the total electric power input in watt-hours during the same period.

6.

EER = Energy Efficiency Ratio - the cooling capacity in BTU’s per hour (BTUH) divided by the power input in watts at any given
set of rating conditions, expressed in BTUH per watt (BTUH/watt).

TABLE 3: SOUND POWER RATINGS

1

UNIT

SIZE

CFM

ESP

BLOWER

SOUND POWER (dB 10

-12

WATTS)

OCTAVE BAND CENTERLINE FREQUENCY (Hz)

SWL

dB(A)

dBA

@ 10Ft

2

IWG

SPEED

kW

63

125

250

500

1000

2000

4000

8000

036

1200

0.60

LOW

0.60

84

84

74

67

69

62

57

52

74

41

048

1600

0.55

HIGH

0.80

85

85

75

68

70

63

58

53

75

42

060

2000

0.45

HIGH

1.00

86

86

76

69

71

64

59

54

76

43

1.

These values have been accessed using a model of sound propagation from a point source into the hemispheric free field. The
dBA values provided are to be used fro reference only. Calculation of dBA values cover matters of system design and the fan
manufacture has no way of knowing the details of each system. This constitutes an exception to any specification or guarantee
requiring a dBA value or sound data in any other form than sound power level ratings.

2.

At a distance of 10 feet from the blower.

Not ARI required