Table 5-1 troubleshooting reference – Xantrex Technology Powerpack 300 User Manual

Page 50

Advertising
background image

Troubleshooting Reference

37

AC appliance
will not
operate;
audible alarm
is sounding.

Battery has discharged to
10.5 V.

XPower Powerpack has
overheated due to poor
ventilation or excessively
warm environmental
conditions.

Turn

OFF

the AC Power

ON

/

OFF

switch and recharge the XPower
Powerpack.

Turn the AC Power

ON

/

OFF

switch

OFF

and allow the

XPower Powerpack to cool for
15 minutes or more. Clear
blocked opening or remove
objects covering the unit, then
restart the XPower Powerpack
and move it to a cooler
environment.

Run time is
less than
expected.

XPower Powerpack
battery is not fully
charged.

AC appliance power
consumption is higher
than expected.

Environmental
temperature is less than
0°C (32°F) or more than
40°C (104°F)

Recharge using the AC charger,
until Battery Status LED is
green.

Check AC appliance power or
wattage rating (or current draw
for 12 V DC appliances) and
compare with Table 3-1 on
page 14 and T
able 3-2 on
page 17.

Operate within correct
temperature range.

Table 5-1 Troubleshooting reference

Problem

Possible Cause

Solution

Advertising