8. Operation

lever is in to the “start” position. (OP6)

6. While holding the unit firmly, pull out the starter

rope quickly until engine fires. (OP7)

(1) choke lever (2) close (3) open
(4) ignition switch (5) start (6) stop
(7) throttle set button

The product is equipped with a centrifugal
clutch mechanism, so the cutting attachment
begins to rotate as soon as the engine is
started by putting the throttle into the start
position. When starting the engine, place the
product onto the ground in a flat clear area and
hold it firmly in place so as to ensure that
neither the cutting part nor the throttle come
into contact with any obstacle when the engine
starts. (OP8)

• Avoid pulling the rope to its end or returning it by

releasing the knob. Such actions can cause
starter failures.

7. Move the choke lever downward to open the

choke. And restart engine. (OP5)

8. Allow the engine to warm up for a several

minutes before starting operation.

1. When restarting the engine immediately after

stopping it, leave the choke open.

2. Overchoking can make the engine hard to start

due to excess fuel. When the engine failed to
start after several attempts, open the choke and
repeat pulling the rope, or remove the spark plug
and dry it.

STOPPING ENGINE (OP6)
1. Release the throttle lever and run the engine for

a half minute.

2. Shift the ignition switch to the STOP position.

NOTE