Operating Limits

975-0128-01-01

4–3

Operating Limits

Power Output

The XPower Inverter 3000 Plus can deliver up to 2500 W continuous and
up to 3000 W for five minutes.

The wattage rating applies to resistive loads such as incandescent lights.

Input Voltage

The allowable inverter input (battery) voltage ranges are shown in the

following table:

Operating Condition

Voltage Range

Comment

Normal

10.5–15 V

Optimum
Performance

12.0–13.0 V

Low Voltage Alarm

11.0 V or less

The audible low battery alarm
sounds.

Low Voltage
Shutdown

less than 10.5 V The inverter shuts down to protect the

battery from being over-discharged.

High Voltage
Shutdown

15.0 V or more

The inverter shuts down to protect
itself from excessive input voltage.
Note: Although the inverter
incorporates over-voltage protection,
it can still be damaged if input
voltage exceeds 16 V.