Technical data – Zanussi ZCG 6600 User Manual
Page 41
TECHNICAL DATA
DIMENSIONS
Height
Width
Depth
Height to hotplate
900mm (nominal)
600mm (nominal)
600mm
(to front of
door panel)
Space for fixing at hotplate level
2mm minimum clearance
Space for fixing above hotplate level
Flush-see important note 'Location of Appliance' page 43.
Minimum space above hotplate
787mm (If a cooker hood is fitted refer to the cooker hood
installation instructions).
Weight of appliance
64.5kg.
Minimum distance from rear wall
5mm (spacer given by pressed spacer on vent panel).
CONNECTIONS
Gas
Rear left hand side of cooker at hotplate level.
Rc½ (½" B.S.P. female).
Electric
220V/240V 50 Hz mains 3 core cable is supplied with an integral, moulded plug fitted
with a 3 amp fuse.
IGNITION
Spark generator
MG7424/1
GRILL
Natural Gas
Heat Input
3.3kW (11263 Btu/h)
Injector Marking
138
HOTPLATE
Natural Gas
R.H.F.
R.H.R.
L.H.R. L.H.F
Heat Input
1.0kW
2.0kW
2.0kW 2.8kW
(3412 Btu/h) (6824 Btu/h) ( 6824 Btu/h) (9554 Btu/h)
Injector Marking
079
104
104
130
MAIN OVEN
Natural Gas
Heat Input
2.4kW (8189Btu/h)
Injector Marking
108
Flame Supervision Device
Diamond'H' GSD 213
Thermostat
Diamond'H' 1100-95/B2
Thermostat By-Pass Marking
69
SECOND OVEN
Natural Gas
Heat Input
2.4kW (8189 Btu/h)
Injector Marking
108
Flame Supervision Device
Diamond 'H' GSD 100/31
Dual Control
Sourdillon 60112/982
GENERAL
Ignition
H. T. Spark
Spark Gap
3-4mm
42