Technical data – Zanussi ZCG 6600 User Manual

Page 41

Advertising
background image

TECHNICAL DATA

DIMENSIONS

Height

Width

Depth

Height to hotplate

900mm (nominal)

600mm (nominal)

600mm
(to front of
door panel)

Space for fixing at hotplate level

2mm minimum clearance

Space for fixing above hotplate level

Flush-see important note 'Location of Appliance' page 43.

Minimum space above hotplate

787mm (If a cooker hood is fitted refer to the cooker hood
installation instructions).

Weight of appliance

64.5kg.

Minimum distance from rear wall

5mm (spacer given by pressed spacer on vent panel).

CONNECTIONS

Gas

Rear left hand side of cooker at hotplate level.
Rc½ (½" B.S.P. female).

Electric

220V/240V 50 Hz mains 3 core cable is supplied with an integral, moulded plug fitted

with a 3 amp fuse.

IGNITION

Spark generator

MG7424/1

GRILL

Natural Gas

Heat Input

3.3kW (11263 Btu/h)

Injector Marking

138

HOTPLATE

Natural Gas

R.H.F.

R.H.R.

L.H.R. L.H.F

Heat Input

1.0kW

2.0kW

2.0kW 2.8kW

(3412 Btu/h) (6824 Btu/h) ( 6824 Btu/h) (9554 Btu/h)

Injector Marking

079

104

104

130

MAIN OVEN

Natural Gas

Heat Input

2.4kW (8189Btu/h)

Injector Marking

108

Flame Supervision Device

Diamond'H' GSD 213

Thermostat

Diamond'H' 1100-95/B2

Thermostat By-Pass Marking

69

SECOND OVEN

Natural Gas

Heat Input

2.4kW (8189 Btu/h)

Injector Marking

108

Flame Supervision Device

Diamond 'H' GSD 100/31

Dual Control

Sourdillon 60112/982

GENERAL

Ignition

H. T. Spark

Spark Gap

3-4mm

42

Advertising