TABLE 10: ELECTRICAL DATA DM078 (6-1/2 TON) STD EFFICIENCY W/O PWRD CONVENIENCE OUTLET

RLA

LRA

FLA

1.5

2

1.5

2

1.5

2

1.5

2

1.5

2

ea.

ea.

ea.

HP

HP

HP

HP

HP

HP

HP

HP

HP

HP

None

--

--

38.0

40.0

43.5 45.5

50

50

50

50

2TP04520925

6.8

18.9

38.0

40.0

43.5 45.5

50

50

50

50

2TP04521825

13.5

37.5

54.6

57.1

61.5 64.0

60

60

70

70

2TP04522425

18

50.0

70.2

72.7

77.1 79.6

80

80

80

80

2TP04523625

25.5

70.8

96.2

98.7 103.1 105.6 100 100

110

110

None

--

--

38.0

40.0

43.5 45.5

50

50

50

50

2TP04520925

9

21.7

38.0

40.0

43.5 45.5

50

50

50

50

2TP04521825

18

43.3

61.9

64.4

68.8 71.3

70

70

70

80

2TP04522425

24

57.7

79.9

82.4

86.8 89.3

80

90

90

90

2TP04523625

34

81.8

110.0 112.5 116.9 119.4 110 125

125

125

None

--

--

20.7 21.7 22.9 23.9 25 25

25

30

2TP04520946

9

11.3

20.7 21.7 22.9 23.9 25 25

25

30

2TP04521846

18

22.6

30.9 32.2 33.7 34.9 35 35

35

35

2TP04522446

24

30.1

40

41.2 42.7 44 40 45

45

45

2TP04523646

34

42.7

55

56.2 57.7 59 60 60

60

60

None

--

--

15.1 16.3 16.9 18.1 20 20

20

20

2TP04520958

9

9.0

15.1 16.3 16.9 18.1 20 20

20

20

2TP04521858

18

18.1

24.7 26.2 26.9 28.4 25 30

30

30

2TP04522458

24

24.1

31.9 33.4 34.1 35.6 35 35

35

40

2TP04523658

34

34.1

43.9 45.4 46.1 47.6 45 50

50

50

*

Maximum HACR breaker of the same AMP size is applicable.

12.8

110.0

1.5

6.2

8.2

5.5

0.0

12.8

110.0

1.5

7.1

54.0

0.8

5.1

44.0

6.2

8.2

3.1

4.1

0.6

2.4

3.6

5.5

0.0

2.2

0.0

460

575

1.8

0.0

Max

Fuse*

Size

(Amps)

Max Fuse* Size

w/Power

Exhaust

(Amps)

FLA

FLA

Actual

KW

Heater

Amps

Min. Circuit

Ampacity

(Amps)

MCA

w/Power

Exhaust

(Amps)

Supply
Blower

Motor FLA

Pwr
Exh

Motor

Pwr

Conv

Outlet

Electric Heater

Model No.

Voltage

Compressors

OD Fan

Motors

208

230

TABLE 11: ELECTRICAL DATA DM078 (6-1/2 TON) STD EFFICIENCY WITH PWRD CONVENIENCE OUTLET

RLA

LRA

FLA

1.5

2

1.5

2

1.5

2

1.5

2

1.5

2

ea.

ea.

ea.

HP

HP

HP

HP

HP

HP

HP

HP

HP

HP

None

--

--

48.0

50.0

53.5 55.5

60

60

60

60

2TP04520925

6.8

18.9

48.0

50.0

53.5 55.5

60

60

60

60

2TP04521825

13.5

37.5

67.1

69.6

74.0 76.5

70

70

80

80

2TP04522425

18

50.0

82.7

85.2

89.6 92.1

90

90

90

100

2TP04523625

25.5

70.8

108.7 111.2 115.6 118.1 110 125

125

125

None

--

--

48.0

50.0

53.5 55.5

60

60

60

60

2TP04520925

9

21.7

48.0

50.0

54.2 56.7

60

60

60

60

2TP04521825

18

43.3

74.4

76.9

81.3 83.8

80

80

90

90

2TP04522425

24

57.7

92.4

94.9

99.3 101.8 100 100

100

110

2TP04523625

34

81.8

122.5 125.0 129.4 131.9 125 125

150

150

None

--

--

25.7 26.7 27.9 28.9 30 30

30

35

2TP04520946

9

11.3

25.7 26.7 27.9 28.9 30 30

30

35

2TP04521846

18

22.6

37.2 38.4 39.9 41.2 40 40

40

45

2TP04522446

24

30.1

46.2 47.5

49 50.2 50 50

50

60

2TP04523646

34

42.7

61.2 62.5

64 65.2 70 70

70

70

None

--

--

19.1 20.3 20.9 22.1 20 25

25

25

2TP04520958

9

9.0

19.1 20.3 21.1 22.6 20 25

25

25

2TP04521858

18

18.1

29.7 31.2 31.9 33.4 30 35

35

35

2TP04522458

24

24.1

36.9 38.4 39.1 40.6 40 40

40

45

2TP04523658

34

34.1

48.9 50.4 51.1 52.6 50 60

60

60

*

12.8

110.0

1.5

230

1.5

5.5

10.0

6.2

8.2

208

110.0

460

575

12.8

Voltage

Compressors

OD Fan

Motors

Supply
Blower

Motor FLA

Pwr
Exh

Motor

Pwr

Conv

Outlet

Electric Heater

Model No.

Max

Fuse*

Size

(Amps)

Max Fuse* Size

w/Power

Exhaust

(Amps)

FLA

FLA

Actual

KW

Heater

Amps

Min. Circuit

Ampacity

(Amps)

MCA

w/Power

Exhaust

(Amps)

Maximum HACR breaker of the same AMP size is applicable.

6.2

8.2

5.5

10.0

7.1

54.0

0.8

3.1

4.1

2.2

5.0

5.1

44.0

0.6

2.4

3.6

1.8

4.0

Advertising