ZELMER 919 User Manual

Page 59

Advertising
background image

63

agent recommended by ZELMER S.A. in the amount and

manner indicated on the label.

„G 478 Entschäumer D” manufactured by the company

BUZIL, Germany.
Prepare the vacuum cleaner for operation according

to section B.

ATTENTION! Use only the large or small atomizing

nozzle for wet vacuum cleaning.

The vacuum cleaner will by default begin operation at the

medium power range. 3 diodes will light on the power

level indicator (9). Set the desired power value (this

function is only available in vacuum cleaners type 919.0)

by pressing the power adjustment buttons +/- (8).

7

Press the pump switch (6).

ATTENTION! The pump may only be switched on when

the cleaning liquid container is filled with the solution

of cleaning liquid and water. The lack of cleaning liquid

manifests in a loud operation of the pump.

If the nozzle does not atomize water although the pump is

switched on, check if the following items are correctly installed:

the cleaning liquid container (press the container), the fastening

of the stub pipe in the valve in the base of the vacuum cleaner

or the fastening of the hose end in the atomizing nozzle, check

if the atomizing nozzle is not clogged.

8

Press the button adjusting the inflow of water to the

nozzle on the hose handle.
If you press the button in a pulsating manner, the water shall

temporarily flow in a slower manner to the nozzle, if you

press and slide the button backwards, the water shall be

continuously supplied to the nozzle.

The handle is also equipped with a slider to adjust the suction

power. Do not uncover this opening while picking up water or

using the wet cleaning function.

ATTENTION! Do not spray the cleaning liquid in one

place on the carpet for too long in order not to soak

the carpet.

After cleaning one part of the carpet stop the spraying

process and dry the carpet by sliding the nozzle back and

forth. Repeat until the whole surface of the carpet is dried.

After ending the spraying process switch off the pump

and press the button adjusting the water inflow to the

nozzle for a moment to “release the pressure”.

ATTENTION! The vacuum cleaner is equipped with a float

which will automatically block the suction if the foam filter

II (32) is heavily dirty or the liquid exceeds the maximum

level. It is manifested by a pulsing limitation of the motor

power and the lighting up of the clogged air inlet indicator

(11) (type 919.0). In such a case switch off the vacuum

cleaner by pressing the on/off button (7), unplug the

appliance, clean the filter and empty the container.

In case of dirt which is difficult to remove moisten the surface

with the washing agent recommended by ZELMER S.A. until

foam is formed. Leave for some time and vacuum with the

vacuum cleaner.

ATTENTION! Make sure the carpet is not soaked.

It may lead to a permanent deformation of the carpet

(folding).

PICKING UP WATER
If you want to use the vacuum cleaner to vacuum liquid in

the container, the vacuum cleaner should be prepared as in

the case of vacuum cleaning with the use of the water filter

module except that:

1. The container should be empty (without water).

2. You are to use atomizing nozzles (large or small), large

atomizing nozzle with the gathering attachment or the

nozzle for picking up water.

ATTENTION! Do not operate the vacuum cleaner with

a full container! Do not vacuum large amounts of liquid

at a time (e.g. with the hose immersed into water).

If the water exceeds the maximum level during vacuuming,

the float will automatically block the suction. The maximum

capacity of the container is about 5 l. In such a case proceed

in the manner described above in the part concerning the

blocking of suction caused by a dirty foam filter (pulsating

motor speed).
END OF OPERATION CLEANING AND MAINTENANCE

Switch off the vacuum cleaner by pressing the on/off

button (7) and unplug the appliance.

Wind the cord by pressing the cord rewind button

(10).

While doing this hold the cord to make sure it is not

tangled and the plug does not hit the vacuum cleaner

housing.

Turn the end of the hose until the tops of the marks

on the end of the hose end and on the vacuum cleaner

housing are in the same position and pull the hose out

of the opening.

Remove the stub pipe of the hose by pressing the red

button on the valve and pull the stub pipe.

Disconnect the telescopic tube from the hose and the

nozzle or brush.

Pour the dirty water out of the container.

It is recommended to wash the container, filters

(disassembly below) and partition thoroughly after each

use – changing water several times.

After using the wet cleaning function thoroughly wash

all attachments used in this process (hose, tubes,

accessories).

ATTENTION! If you do not clean the above-mentioned

parts or clean them insufficiently it may lead to the loss

of the filtration capabilities of the inserts and foam and

cause the formation of bacteria and mites.

Dry all the cleaned parts thoroughly before reassembly.

Advertising