6 bit-strobe command, 1 principle of bit-strobe, Bit-strobe command – Delta DVP-0204520-03 User Manual

Page 25: Devicenet network scanner dvpdnet-sl

Advertising
background image

DeviceNet Network Scanner DVPDNET-SL

6 Bit-Strobe

Command

6.1 Principle of Bit-Strobe

Bit-strobe is one of the standard I/O transmission methods for DeviceNet. The length of command is fixed to 8

bytes (i.e. 64 bits), and every bit corresponds to a slave.

Corresponding nodes on the network

PLC

device

b15

b14

b13

…

b1

b0

D6282

Node 15

Node 14

Node 13

…

Node 1

Node 0

D6283

Node 31

Node 30

Node 29

…

Node 17

Node 16

D6284

Node 47

Node 46

Node 45

…

Node 33

Node 32

D6285

Node 63

Node 62

Node 61

…

Node 49

Node 48

When b0 of D6282 = 0, the node 0 equipment will be selected, and it will need to respond with a message to

the master. When b0 and b1 of D6282 = 0, the node 0 and node 1 equipment will be selected, and they will be

to respond with a message to the master.

b0

b1

b17

b15 b14

b30

b2

b18

b16

b31

D8283

Node 0
Node 1

Node 2

Node 14

D6282

In the bit-strobe mode, the master will not send control data to the slave node. However, when its

corresponding bit is set to 0, the slave node will have to respond with I/O data to the master. When its

corresponding bit is set to 1, the slave node will not have to respond with I/O data to the master.

DVP-PLC Operation Manual

22

Advertising