2. replacing projection lamp, 2. r, Eplacing – 3M MP8760 User Manual

Page 23: Rojection, Caution

Advertising
background image

18

3M

Multimedia Projector MP8760

3M IPC 2000

ENGLISH

6-2.

Replacing Projection Lamp

The NTP lamp of the projector has a limited lifetime of approximately 1500 hours. If the projected image appears
dark or a red lamp life indicator bar displays during projector startup, you should change the lamp and air filter.

!

!

!

!

Important Note

This lamp contains mercury. Consult your local
hazardous waste regulations and
dispose of this lamp in a proper manner.

!

Caution

Always unplug the projector when changing the lamp.
There are high voltage parts inside the cabinet that
may cause electric shock.

!

Caution

Allow the projector to cool down for 30 minutes.
Lamp and adjacent metal parts become extremely hot
and can cause burns to your fingers.

1. Press the Standby/On button on the operator touch panel or remote control.

Wait for the fan motor to cycle off.

2. Turn the main power switch to OFF and unplug the projector power cord.
3. Set the projector on a sturdy surface with the front of the projector facing you.
4. Press and hold the lamp door button

(1)

with your index finger. Slide your finger to the right and depress the

lock tab

(2)

. Pull outward on the lamp door

(4)

to hinge it to the right side and access the lamp cartridge

(5)

.

5. Unscrew two retaining screws

(3)

securing the lamp cartridge

(5)

.

6. Grasp handle

(6)

and carefully pull the lamp cartridge

(5)

out of the projector.

7. Carefully insert the new lamp cartridge

(5)

and secure with retaining screws

(3)

.

8. Close the lamp door

(4)

tightly until the lock tab

(2)

slides into the locked position.

9. Go to the Advanced Setup menu and reset the lamp life display to zero. (see 6-3. Lamp Life Indicator)

Figure 6-2. Changing the lamp cartridge

1

5

6

4

2

3

EPS-43A

Advertising